Skip to main content
Siemens 3VA2463-5KP32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-5KP32-0DH0 SENTRON MCCB, 630 A, 187 kA at 24

MPN3VA2463-5KP32-0DH0

Siemens SENTRON molded case circuit breaker, 3VA2463-5KP32-0DH0, 3-pole, 630 A, 187 kA at 240 V, with ETU850 electronic trip unit and undervoltage release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2463-5KP32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2463-5KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2463-5KP32-0DH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C630 A
Current at 45 °C600 A
Current at 50 °C570 A
Current at 55 °C540 A
Current at 60 °C510 A
Current at 65 °C480 A
Current at 70 °C450 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.164.5 W

Protection & Trip Unit

3VA2463-5KP32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850

Construction & Connection

3VA2463-5KP32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2463-5KP32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2463-5KP32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2463-5KP32-0DH0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

What this MCCB delivers for your panel

The Siemens 3VA2463-5KP32-0DH0 is a 3-pole SENTRON molded case circuit breaker rated for 630 A continuous current, with a breaking capacity of 187 kA at 240 V — that's a serious fault-current rating for main feeders or large motor branch circuits where the available short-circuit current is high. The ETU850 electronic trip unit gives you adjustable overload and short-circuit protection curves, so you can coordinate with downstream devices without nuisance tripping.

Derating and thermal management

The 630 A rating holds at 40 °C ambient; above that you need to derate. At 45 °C it's 600 A, at 50 °C it's 570 A, and it drops to 450 A at 70 °C. That matters when you're packing this into a warm enclosure — plan for the actual ambient, not the catalog number. Maximum power loss is 164.5 W, so ventilation or forced air may be needed in a tight cabinet.

Breaking capacity across voltages

Short-circuit performance varies by system voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V. That's a strong curve — it stays usable even on 690 V systems where many MCCBs drop off steeply.

Auxiliary and release options

Comes with an undervoltage release (UVR) for safety disconnects, plus 2 auxiliary switches and 1 trip alarm switch (HQ type) for status feedback to a PLC or annunciator. Communication function is built in — this variant is ready for remote monitoring without an add-on module.

Frequently asked questions

Does 3VA2463-5KP32-0DH0 include an undervoltage release?

Yes, it comes with an undervoltage release (UVR) as standard.

What trip unit does this MCCB use?

It uses the ETU850 electronic trip unit, which offers adjustable protection curves.

MPN
3VA2463-5KP32-0DH0