The Siemens SENTRON 3VA2463-5KP32-0HC0 is a 3-pole molded case circuit breaker rated for 630 A continuous current at 40 °C, with a maximum breaking capacity of 187 kA at 240 V. That 187 kA figure drops to 121 kA at 415 V and 440 V, then to 75.6 kA at 500 V, and further to 9 kA at 690 V — the SCCR headroom you need for high-fault installations like transformer secondaries or large motor control centers. The continuous current derates predictably with ambient temperature: 600 A at 45 °C, 570 A at 50 °C, down to 450 A at 70 °C. It also carries a communication function via the SENTRON communication module.

Siemens 3VA2463-5KP32-0HC0 SENTRON MCCB, 630 A, 187 kA
MPN3VA2463-5KP32-0HC0
Siemens SENTRON 3VA2463-5KP32-0HC0, molded case circuit breaker, 3-pole, 630 A at 40 °C, 187 kA at 240 V, line protection with communication function.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Basic switch (supplied) ref. | 3VA2463-5KP32-0AA0 |
| Integrated auxiliary / alarm switch ref. | 3VA9988-0AA12 |
| Parameter | Value |
|---|---|
| Number of poles | 3 |
| Rated operational voltage Ue (AC) | 690 V |
| Rated insulation voltage Ui | 800 V |
| Current at 40 °C | 630 A |
| Current at 45 °C | 600 A |
| Current at 50 °C | 570 A |
| Current at 55 °C | 540 A |
| Current at 60 °C | 510 A |
| Current at 65 °C | 480 A |
| Current at 70 °C | 450 A |
| Switching capacity class | M |
| Breaking capacity at 240 V | 187 kA |
| Breaking capacity at 415 V | 121 kA |
| Breaking capacity at 440 V | 121 kA |
| Breaking capacity at 500 V | 75.6 kA |
| Breaking capacity at 690 V | 9 kA |
| Power loss, max. | 162 W |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | ETU850 |
| Overcurrent protection function | LSI |
| Ground-fault monitoring | Without |
| Grounding protection function | No |
| Parameter | Value |
|---|---|
| Main circuit connection type | on both sides nut keeper kit |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Undervoltage release | No |
| Voltage trigger | Yes |
| Trip indicator | No |
| Communication function | Yes |
| Measurement function | Yes |
| Motor drive option | Yes |
| Auxiliary CO contacts | 2 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
| Parameter | Value |
|---|---|
| Mechanical service life (operating cycles), typ. | 20 000 |
| Height | 248 mm |
| Width | 138 mm |
| Depth | 110 mm |
| Height (in) | 9.76 in |
| Width (in) | 5.43 in |
| Depth (in) | 4.33 in |
Product details
Frequently asked questions
Does this breaker include a shunt trip or undervoltage release?
It includes a shunt trip (STL) release and two auxiliary switches (HQ). No undervoltage release or ground-fault monitoring is fitted on this variant.
MPN
3VA2463-5KP32-0HC0