Siemens 3VA2463-5KQ32-0AH0 3VA2 IEC Frame 630, 55kA @ 415V,

MPN3VA2463-5KQ32-0AH0

Siemens 3VA2 IEC frame 630, breaking capacity class M, Icu=55kA @ 415V, 3-pole, line protection ETU860, LSIG, In=630A, overload protection Ir=250A...630A, short-circuit protection Isd=0.6..9x In, Ii=1.5..9x In, ground-fault protection Ig=0.2...1 x In, tg=0.05-0.8s, 2 auxiliary switches, 1 trip alarm switch.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 3VA2463-5KQ32-0AH0 is a 3-pole IEC frame 630 molded-case circuit breaker in the 3VA2 series, rated for breaking capacity class M with an Icu of 55 kA at 415 V AC. It carries the ETU860 electronic trip unit configured for LSIG protection — long-time, short-time, instantaneous, and ground-fault — with an In of 630 A. Overload protection (Ir) is adjustable from 250 A to 630 A; short-circuit protection (Isd) from 0.6 to 9 times In, and instantaneous pickup (Ii) from 1.5 to 9 times In. Ground-fault protection is switchable, with pickup (Ig) from 0.2 to 1 times In and time delay (tg) from 0.05 to 0.8 seconds. The breaker ships with two auxiliary switches and one trip alarm switch.

What the Ratings Mean for Fit

The 55 kA Icu at 415 V defines the maximum short-circuit current the breaker can safely interrupt without damage — critical for verifying SCCR compliance at the panel level. The ETU860's LSIG profile covers full-spectrum protection: long-time for cable/overload, short-time and instantaneous for bolted faults, and ground-fault for arcing or leakage paths. The adjustable ground-fault delay (0.05–0.8 s) allows coordination with downstream devices. Two auxiliary switches and one trip alarm switch provide status feedback for PLC or SCADA inputs.

Frequently asked questions

What is the breaking capacity of 3VA2463-5KQ32-0AH0?

The breaker has a breaking capacity class M with an Icu of 55 kA at 415 V AC.

What protection functions does the ETU860 trip unit provide?

The ETU860 provides LSIG protection: long-time, short-time, instantaneous, and ground-fault. Overload protection Ir is adjustable 250 A to 630 A; short-circuit Isd is 0.6 to 9 times In; instantaneous Ii is 1.5 to 9 times In; ground-fault Ig is 0.2 to 1 times In with a time delay tg of 0.05 to 0.8 seconds.

Where can I buy 3VA2463-5KQ32-0AH0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2463-5KQ32-0AH0