Skip to main content
Siemens 3VA2463-6HL32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-6HL32-0AA0 SENTRON MCCB, 630 A, 3-Pole, ETU3

MPN3VA2463-6HL32-0AA0
Active

Siemens SENTRON 3VA2463-6HL32-0AA0, molded case circuit breaker, 3-pole, 630 A, ETU320 electronic trip unit, line protection design.

$886.46Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-6HL32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2463-6HL32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V9 kA
Power loss, max.162 W
3VA2463-6HL32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2463-6HL32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-6HL32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2463-6HL32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-6HL32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens 3VA2463-6HL32-0AA0 is a SENTRON molded case circuit breaker rated for 630 A continuous current at 40 °C, with a 3-pole configuration and an ETU320 electronic trip unit designed for line protection. The ETU320 provides adjustable long-time, short-time, and instantaneous protection, giving you selectivity headroom downstream without nuisance tripping on motor inrush. Short-circuit breaking capacity ranges from 242 kA at 240 VAC down to 9 kA at 690 VAC — the 242 kA figure at 240 V tells you this breaker handles high-fault utility feeds or transformer secondaries where available fault current is substantial. The thermal derating curve is published from 40 °C up to 70 °C: 630 A at 40 °C, 612 A at 45 °C, 593 A at 50 °C, 575 A at 55 °C, 557 A at 60 °C, 538 A at 65 °C, and 520 A at 70 °C. If your panel ambient runs 50 °C, you lose about 6 % of the continuous rating — factor that into your load calc. Power loss is listed at 162 W maximum — relevant for enclosure thermal management when multiple breakers are ganged in a switchboard section.

The SENTRON 3VA series is Siemens' current-generation MCCB platform, so accessory compatibility is current-catalog.

Dimensions: 248 mm height, 138 mm width, 110 mm depth. If you need those options, look at the -6HL32-0AA0 suffix variants in the same frame. The storage maximum exceeds the operating max — that governs shipping and warehousing, not running conditions.

Frequently asked questions

Does the 3VA2463-6HL32-0AA0 include ground-fault monitoring?

No, this variant is specified without ground-fault monitoring. It is a line-protection breaker with the ETU320 electronic trip unit.

MPN
3VA2463-6HL32-0AA0