Siemens 3VA2463-6HL32-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-6HL32-0AG0 MCCB, 630 A, 3-Pole, ETU320

MPN3VA2463-6HL32-0AG0

Siemens SENTRON 3VA2463-6HL32-0AG0, molded case circuit breaker, 3-pole, 630 A at 40 °C, 242 kA breaking capacity at 240 V, ETU320 electronic trip unit, line protection version.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-6HL32-0AG0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2463-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2463-6HL32-0AG0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V40 kA
Power loss, max.162 W
3VA2463-6HL32-0AG0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2463-6HL32-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-6HL32-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2463-6HL32-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-6HL32-0AG0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

630 A MCCB with 242 kA interrupting capacity — the selectivity anchor for high-fault panels

The Siemens SENTRON 3VA2463-6HL32-0AG0 is a 3-pole molded case circuit breaker rated for 630 A continuous at 40 °C, with a maximum interrupting capacity of 242 kA at 240 V. That 242 kA figure is the headline: it lets this breaker serve as the main or tie device in a switchboard where fault current exceeds 200 kA — common in large industrial services and data-center utility entrances. The ETU320 electronic trip unit provides LI (long-time and instantaneous) protection curves, adjustable via the front dials, so you tune the pickup and delay to coordinate with downstream feeders without swapping trip packs. Rated insulation voltage is 800 V, and the breaker carries a full thermal derating table: 612 A at 45 °C, 593 A at 50 °C, 575 A at 55 °C, 557 A at 60 °C, 538 A at 65 °C, and 520 A at 70 °C. Maximum power loss is 162 W, which matters for enclosure heat-rise calculations in a sealed or high-density cabinet.

Mounting and integration — panel footprint and wiring

The breaker mounts with four screws through the base — no DIN-rail clip — so plan for a drilled backplate.

Breaking capacity by voltage — coordination data for the engineer

Interrupting capacity varies by system voltage: 242 kA at 240 V, 187 kA at both 415 V and 440 V, 121 kA at 500 V, and 40 kA at 690 V. The 690 V rating at 40 kA is enough for most 690 V drives and motor control centers.

Frequently asked questions

What is the breaking capacity of 3VA2463-6HL32-0AG0 at 415 V?

187 kA at 415 V, which is the same rating as at 440 V. This is sufficient for most 400 V-class industrial networks.

What trip unit does this MCCB use?

The ETU320 electronic trip unit with LI (long-time and instantaneous) protection. Adjustable via front dials.

Where can I buy 3VA2463-6HL32-0AG0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does this breaker include a shunt trip or undervoltage release?

No. This variant ships without any auxiliary release, undervoltage release, or communication function. It includes one auxiliary switch and one trip alarm switch.

MPN