Skip to main content
Siemens 3VA2463-6HL32-0BF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-6HL32-0BF0 630A 85kA ICB, ETU320 LI

MPN3VA2463-6HL32-0BF0

Siemens 3VA2 IEC frame 630, breaking capacity class H, 85 kA @ 415 V, 3-pole, ETU320 LI, In 630 A, overload Ir 250–630 A, short-circuit Ii 1.5–9x In, undervoltage release 24 V DC, 1 auxiliary switch HQ, 1 trip alarm switch HQ, nut keeper kit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

85 kA at 415 V — what that means for your distribution board

The 3VA2463-6HL32-0BF0 is a Siemens 3VA2 IEC frame 630 circuit breaker with breaking capacity class H, rated Icu = 85 kA at 415 V AC. At 85 kA SCCR, this breaker coordinates with upstream switchgear without requiring a current-limiting fuse or reactor, keeping the fault loop impedance low for downstream devices.

ETU320 LI trip unit — adjustable protection, not fixed

The ETU320 electronic trip unit provides LI (long-time and instantaneous) protection. Overload protection Ir is adjustable from 250 A to 630 A, matching the breaker's In of 630 A — so one frame covers a 250 A feeder or a 630 A main by dialing the pickup. Short-circuit protection Ii is adjustable from 1.5x to 9x In (945 A to 5670 A at the 630 A setting), letting you set instantaneous pickup above motor inrush or transformer magnetizing current without nuisance tripping. The LI curve suits line protection for cables, busbars, and transformers where ground-fault (G) protection is handled separately or downstream.

Integrated undervoltage release and auxiliary contacts

Also includes one HQ auxiliary switch and one HQ trip alarm switch. The HQ designation indicates a high-rupturing-capacity microswitch rated for control-circuit isolation, not just signaling. Both switches give the PLC or SCADA positive indication of breaker position and trip status without relying on the UVR coil state.

What the nut keeper kit saves you

On a panel build with multiple 3VA2 breakers, that adds up to measurable labor savings per unit.

Frequently asked questions

What is the breaking capacity of this breaker?

Icu = 85 kA at 415 V AC, breaking capacity class H per IEC 60947-2.

What trip unit does this breaker use and what are the adjustment ranges?

ETU320 LI electronic trip unit. Overload Ir adjustable 250–630 A; instantaneous Ii adjustable 1.5–9x In (945–5670 A at 630 A setting).

Does this breaker include auxiliary contacts and an undervoltage release?

Yes. Factory-fitted with a 24 V DC undervoltage release, one HQ auxiliary switch, and one HQ trip alarm switch.

Where can I buy 3VA2463-6HL32-0BF0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no online stock count or list price is published for this order code.

MPN
3VA2463-6HL32-0BF0