Skip to main content
Siemens 3VA2463-6HL32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-6HL32-0DH0 SENTRON MCCB, 630 A, 3-Pole

MPN3VA2463-6HL32-0DH0

Siemens SENTRON 3VA2463-6HL32-0DH0, molded case circuit breaker, 3-pole, 630 A rated continuous current, ETU320 electronic trip unit, line protection version, 242 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-6HL32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2463-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2463-6HL32-0DH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V40 kA
Power loss, max.164.5 W
3VA2463-6HL32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2463-6HL32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-6HL32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2463-6HL32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-6HL32-0DH0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

The Siemens SENTRON 3VA2463-6HL32-0DH0 is a 3-pole molded case circuit breaker (MCCB) rated for 630 A continuous current at 40 °C ambient, using the ETU320 electronic trip unit for adjustable overload and short-circuit protection. At 240 V it interrupts 242 kA; at 415 V and 440 V that drops to 187 kA, then 121 kA at 500 V, and 40 kA at 690 V — so the breaker's fault-clearing capability scales with system voltage, and the 690 V figure governs its use on 480/277 V or 600 V delta services where available fault current exceeds 40 kA. The ETU320 release gives you adjustable long-time pickup, short-time pickup, and instantaneous settings, plus a trip indicator for fast fault isolation.

Current derating — the real-world continuous current at your ambient

If your panel runs hotter — and most enclosed switchboards do — the breaker derates linearly: 612 A at 45 °C, 593 A at 50 °C, 575 A at 55 °C, 557 A at 60 °C, 538 A at 65 °C, and 520 A at 70 °C (–). That 70 °C figure is also the maximum operating ambient, so the breaker can sit in a hot enclosure without forced cooling, but you lose 110 A of headroom. For a 600 A feeder in a 50 °C switchroom, this breaker still carries the load; for a 630 A bus at 60 °C, it's marginal — you'd step up to the next frame.

Mechanical endurance and power loss

The breaker is rated for 15,000 mechanical operations. Maximum power loss is 164.5 W at rated current.

Physical fit — panel cutout and footprint

Frequently asked questions

What does the ETU320 trip unit do on this breaker?

The ETU320 is an electronic trip unit that provides adjustable long-time (overload), short-time, and instantaneous protection. It enables selective coordination downstream by allowing a deliberate time delay before tripping on high faults, so only the faulted branch opens.

MPN
3VA2463-6HL32-0DH0