Siemens 3VA2463-6HL32-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-6HL32-0HH0 SENTRON MCCB, 630 A, 3-Pole, 110

MPN3VA2463-6HL32-0HH0

Siemens SENTRON molded case circuit breaker, 3VA2463-6HL32-0HH0, 3-pole, 630 A, line protection, interrupting capacity 242 kA at 240 V, depth 110 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-6HL32-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2463-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2463-6HL32-0HH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V9 kA
Power loss, max.162 W
3VA2463-6HL32-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2463-6HL32-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-6HL32-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2463-6HL32-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-6HL32-0HH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Its interrupting capacity reaches 242 kA at 240 V AC, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 9 kA at 690 V — figures that determine the available fault current the breaker can safely clear without upstream coordination failure. The adjustable thermal-magnetic trip unit covers a range from 945 A minimum to 5 670 A maximum, so it can be tuned to protect a specific feeder or transformer without swapping the breaker frame.

Derating and thermal budget

Continuous current derates with ambient temperature: 630 A at 40 °C drops to 612 A at 45 °C, 593 A at 50 °C, 575 A at 55 °C, 557 A at 60 °C, 538 A at 65 °C, and 520 A at 70 °C. Maximum power loss is 162 W, which factors into enclosure ventilation sizing — particularly in a sealed, high-ambient cabinet.

The basic switch is order code 3VA2463-6HL32-0AA0; the -0HH0 suffix adds the factory-fitted accessories above.

Dimensions are 248 mm height, 138 mm width, and 110 mm depth — the depth is the critical dimension for enclosure depth clearance on a standard DIN-rail or backplate mount. The part carries a trip indicator and a voltage trigger for external monitoring.

Frequently asked questions

What is the interrupting capacity of 3VA2463-6HL32-0HH0 at 415 V?

At 415 V AC the interrupting capacity is 187 kA.

What is the depth of this MCCB?

The depth is 110 mm (4.33 in).

Does this breaker include a shunt trip?

Yes, it is factory-fitted with a shunt trip release (STL) for remote tripping.

Where can I buy 3VA2463-6HL32-0HH0 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.