Skip to main content
Siemens 3VA2463-6JP32-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-6JP32-0BC0 SENTRON MCCB, 630 A, 3-Pole, 242

MPN3VA2463-6JP32-0BC0

Siemens SENTRON 3VA2463-6JP32-0BC0, molded case circuit breaker, 3-pole, 630 A continuous at 40 °C, 242 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-6JP32-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2463-6JP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2463-6JP32-0BC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C600 A
Current at 50 °C570 A
Current at 55 °C540 A
Current at 60 °C510 A
Current at 65 °C480 A
Current at 70 °C450 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V9 kA
Power loss, max.164.5 W
3VA2463-6JP32-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2463-6JP32-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-6JP32-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2463-6JP32-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-6JP32-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Current Ratings and Derating

The 3VA2463-6JP32-0BC0: The continuous current rating of 630 A is specified at 40 °C ambient. For higher ambient temperatures, derate per the following: 600 A at 45 °C, 570 A at 50 °C, 540 A at 55 °C, 510 A at 60 °C, 480 A at 65 °C, and 450 A at 70 °C. Maximum power loss is 164.5 W.

Breaking Capacity by Voltage

Breaking capacity varies with system voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 9 kA at 690 V. The adjustable trip range spans from a minimum of 945 A to a maximum of 5,670 A.

Physical Dimensions and Mounting

Dimensions: 138 mm wide, 248 mm high, 110 mm deep. Designed for panel-mount installation in switchgear or distribution boards. The 3-pole form factor fits standard MCCB cutouts.

Built-in Accessories and Communication

The basic switch is order code 3VA2463-6JP32-0AA0. A communication function is included, supporting integration into higher-level monitoring or control systems.

Frequently asked questions

What is the breaking capacity of 3VA2463-6JP32-0BC0 at 240 V?

242 kA at 240 V, with 187 kA at 415 V and 440 V, 121 kA at 500 V, and 9 kA at 690 V.

What is the continuous current rating and derating for 3VA2463-6JP32-0BC0?

630 A at 40 °C, derating to 450 A at 70 °C. Full derating curve: 600 A at 45 °C, 570 A at 50 °C, 540 A at 55 °C, 510 A at 60 °C, 480 A at 65 °C, 450 A at 70 °C.

What are the physical dimensions of 3VA2463-6JP32-0BC0?

138 mm wide, 248 mm high, 110 mm deep.

Where can I buy 3VA2463-6JP32-0BC0?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
3VA2463-6JP32-0BC0