Siemens 3VA2463-6KP42-0DD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-6KP42-0DD0 Circuit Breaker, 630A, 85kA @ 415

MPN3VA2463-6KP42-0DD0

Siemens 3VA2 IEC frame 630, breaking capacity class H, Icu=85kA @ 415V, 4-pole, line protection ETU850, LSI, In=630A, overload protection Ir=250A...630A, short-circuit protection Isd=0.6..9x In, Ii=1.5..9x In, N conductor protection adjustable (OFF, up to 100%), nut keeper kit, undervoltage release 208-230V AC 50/60Hz, 3 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA2463-6KP42-0DD0 is a 4-pole IEC frame 630 molded case circuit breaker with breaking capacity class H, delivering an Icu of 85 kA at 415 V AC. It carries the ETU850 electronic trip unit configured for LSI protection — long-time (Ir), short-time (Isd), and instantaneous (Ii) — with the continuous current rating In fixed at 630 A. The overload protection Ir is adjustable from 250 A to 630 A, the short-time pickup Isd from 0.6 to 9 times In, and the instantaneous pickup Ii from 1.5 to 9 times In. Neutral conductor protection is adjustable from OFF up to 100% of the phase setting. A nut keeper kit is included for secure mounting.

For a 630 A frame, the adjustable Ir from 250 A to 630 A lets you match the thermal protection to the actual load cable or busway rating, not the frame size. The Isd and Ii ranges (0.6–9× In and 1.5–9× In respectively) give selectivity headroom downstream — you can set the short-time pickup above the let-through of feeder breakers to avoid nuisance tripping on motor-start inrush. The neutral protection adjustment (OFF to 100%) is useful on 4-wire systems where the neutral conductor may be undersized relative to the phases.

Deployment context

This breaker mounts in a standard IEC distribution panel or switchboard — the nut keeper kit supplied secures it against vibration on the mounting plate. The undervoltage release (208–230 V AC) provides automatic trip on loss of control voltage, which is typical for emergency-stop circuits or mains-monitoring schemes in industrial power distribution.

Frequently asked questions

Where can I buy the 3VA2463-6KP42-0DD0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of this circuit breaker?

The breaking capacity class H gives an Icu of 85 kA at 415 V AC per IEC 60947-2.

What trip unit and protection functions does the 3VA2463-6KP42-0DD0 have?

It uses the ETU850 electronic trip unit with LSI protection: long-time (Ir adjustable 250–630 A), short-time (Isd adjustable 0.6–9× In), and instantaneous (Ii adjustable 1.5–9× In). Neutral conductor protection is adjustable from OFF to 100%.