Skip to main content
Siemens 3VA2463-6KQ32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-6KQ32-0KL0 Circuit Breaker, 85kA @ 415V, 630

MPN3VA2463-6KQ32-0KL0

Siemens 3VA2 IEC frame 630, breaking capacity class H, Icu=85kA @ 415V, 3-pole, line protection ETU860, LSIG, In=630A, overload protection Ir=250A...630A, short-circuit protection Isd=0.6..9x In, Ii=1.5..9x In, N conductor protection optional, up to 160% ground-fault protection, shunt trip left 208-277V AC 50/60Hz, 2 auxiliary switches HQ, 1 trip alarm switch HQ, 1 electrical alarm switch.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What this 630A frame breaker carries

The Siemens 3VA2463-6KQ32-0KL0 is a 3-pole IEC frame 630 circuit breaker with a breaking capacity class H — 85 kA at 415 V. The ETU860 trip unit gives you LSIG protection: long-time (overload), short-time, instantaneous, and ground-fault, all programmable. Overload protection (Ir) is adjustable from 250 A to 630 A, short-time pickup (Isd) from 0.6 to 9× In, and instantaneous pickup (Ii) from 1.5 to 9× In. Ground-fault protection can be switched off; when active, Ig adjusts from 0.2 to 1× In with a time delay tg from 0.05 to 0.8 s. Neutral protection is optional via an external current transformer, up to 160% of In.

Built-in accessories and control voltage

All auxiliary contacts are wired and ready; no separate order for a signal block. For an integrator: verify the shunt trip coil matches your control transformer tap before commissioning — 208 V and 277 V are different taps on a 480 V delta-to-wye transformer.

Frequently asked questions

What is the breaking capacity of this breaker?

The 3VA2463-6KQ32-0KL0 has a breaking capacity class H with Icu = 85 kA at 415 V AC, which means it can safely interrupt fault currents up to 85 kA at that voltage without upstream devices needing to clear the fault.

What trip unit and protection functions does it have?

It uses an ETU860 electronic trip unit providing LSIG protection: long-time overload (Ir adjustable 250–630 A), short-time (Isd 0.6–9× In), instantaneous (Ii 1.5–9× In), and ground-fault (Ig 0.2–1× In, tg 0.05–0.8 s). Ground-fault can be switched off. Neutral protection is optional via external CT.

What accessories are included on this breaker?

It includes a shunt trip (left side, 208–277 V AC 50/60 Hz), two auxiliary switches (HQ), one trip alarm switch (HQ), and one electrical alarm switch — all factory-installed.

Where can I buy 3VA2463-6KQ32-0KL0 and what is the price?

This breaker is sourced to order against an RFQ through our independent distribution network. Availability and current pricing are confirmed at quote time — submit an RFQ for the commercial details.

MPN
3VA2463-6KQ32-0KL0