Skip to main content
Siemens 3VA2463-7HK32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-7HK32-0AA0 SENTRON MCCB, 630 A, 3-Pole, ETU3

MPN3VA2463-7HK32-0AA0
Active

Siemens SENTRON 3VA2463-7HK32-0AA0, molded case circuit breaker, 3-pole, 630 A, ETU340 electronic trip unit, line protection, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-7HK32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2463-7HK32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V9 kA
Power loss, max.162 W
3VA2463-7HK32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU340
Overcurrent protection functionELISA LI
Ground-fault monitoringWithout
3VA2463-7HK32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-7HK32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2463-7HK32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-7HK32-0AA0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens SENTRON 3VA2463-7HK32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 630 A continuous current at 40 °C, with an ETU340 electronic trip unit configured for line protection. This is a high-frame breaker sized for main feeders or large motor branch circuits in industrial switchgear. The 630 A rating is the uninterrupted current it carries under normal load; the thermal derating curve matters when the breaker lives inside a hot enclosure — at 50 °C it carries 593 A, at 60 °C it carries 557 A, and at 70 °C it carries 520 A. The interrupting ratings are the real headline here: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 9 kA at 690 V. The ETU340 is an electronic trip unit with adjustable long-time, short-time, and instantaneous pickup settings — it's not a fixed thermal-magnetic. That means you can coordinate selectivity with downstream breakers by dialing in the time-current curve, which is essential for a main breaker feeding multiple sub-feeders. The unit has no trip indicator, no undervoltage release, and no communication function — it's a standalone overcurrent protector, not a smart breaker. If you need remote monitoring or shunt-trip capability, you'll add those as optional accessories; the product extension for a motor drive is listed as available.

Panel integration — dimensions and mounting

The 162 W maximum power loss at full rated current generates heat that must be dissipated — if you're packing multiple breakers in a small enclosure, factor that into your thermal calculation to avoid nuisance tripping from ambient rise.

Frequently asked questions

Where can I buy 3VA2463-7HK32-0AA0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the closest functional alternative — 5SQ2370-2YA05?

The 5SQ2370-2YA05 is an older-generation Siemens MCCB that the 3VA series replaced. The 3VA2463-7HK32-0AA0 is the current-production equivalent in terms of frame size and interrupting capacity, but verify the mounting footprint and bus-bar spacing before substituting — the 3VA frame dimensions differ from the 5SQ series.

What are the key ratings for 3VA2463-7HK32-0AA0?

630 A continuous at 40 °C, 3-pole, ETU340 electronic trip unit, interrupting ratings of 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 9 kA at 690 V. Rated insulation voltage is 800 V. Dimensions are 248 x 138 x 110 mm (H x W x D).

MPN
3VA2463-7HK32-0AA0