Skip to main content
Siemens 3VA2463-7HL32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-7HL32-0AD0 SENTRON MCCB, 630 A, 3-Pole, Line

MPN3VA2463-7HL32-0AD0

Siemens SENTRON 3VA2463-7HL32-0AD0, molded case circuit breaker, 3-pole, 630 A rated continuous current Iu, line protection, ETU320 release, 3 auxiliary switches HQ, 110 x 138 x 248 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2463-7HL32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2463-7HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2463-7HL32-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.162 W
3VA2463-7HL32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2463-7HL32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-7HL32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2463-7HL32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-7HL32-0AD0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

630 A MCCB for high-current distribution

Breaking capacity runs 330 kA at 240 V, 242 kA at 415/440 V, 187 kA at 500 V, and 52.5 kA at 690 V.

Current derating and thermal limits

Rated continuous current derates with ambient temperature: 630 A at 40 °C, 612 A at 45 °C, 593 A at 50 °C, 575 A at 55 °C, 557 A at 60 °C, 538 A at 65 °C, 520 A at 70 °C. The panel OEM wireman should apply these derating factors when sizing busbars and selecting enclosure ventilation — the 162 W heat dissipation at full load is non-trivial. Latching endurance is rated at 15,000 cycles — adequate for main breaker duty where switching is infrequent, but not for frequent motor-starting applications.

The breaker ships with 3 auxiliary switches HQ (order code 3VA9608-0BB24) and the ETU320 electronic trip unit. The supplied basic switch is 3VA2463-7HL32-0AA0. No undervoltage release, no voltage trigger, no communication function, no phase failure detection, and no ground fault monitoring are included — this is a pure line-protection device.

Frequently asked questions

Where can I buy 3VA2463-7HL32-0AD0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the breaking capacity of 3VA2463-7HL32-0AD0 at 415 V?

242 kA at 415 V, with 330 kA at 240 V, 242 kA at 440 V, 187 kA at 500 V, and 52.5 kA at 690 V.

What trip unit does 3VA2463-7HL32-0AD0 use?

The ETU320 electronic trip unit, a line-protection release without communication or ground-fault monitoring.

MPN
3VA2463-7HL32-0AD0