Skip to main content
Siemens 3VA2463-7HL32-0BL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-7HL32-0BL0 MCCB, 630 A, 3-Pole, 330 kA at 24

MPN3VA2463-7HL32-0BL0

Siemens SENTRON 3VA2463-7HL32-0BL0, molded case circuit breaker, 3-pole, 630 A continuous, line protection, 330 kA at 240 V, undervoltage release, auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-7HL32-0BL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2463-7HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2463-7HL32-0BL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V9 kA
Power loss, max.164.5 W
3VA2463-7HL32-0BL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2463-7HL32-0BL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-7HL32-0BL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2463-7HL32-0BL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-7HL32-0BL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens SENTRON 3VA2463-7HL32-0BL0 is a 3-pole molded case circuit breaker rated for 630 A continuous at 40 °C, with a breaking capacity of 330 kA at 240 V and 242 kA at 415 V. It's designed for line protection and comes fitted with an undervoltage release plus a full set of auxiliary switches — two aux, one trip alarm, one electrical alarm. This is a panel-mounted unit, 248 mm tall by 138 mm wide by 110 mm deep, so it'll fit a standard MCCB slot in most distribution boards.

The 630 A continuous rating at 40 °C is the headline number, but if your panel runs hotter — and most do inside an enclosure — you need the derating curve: at 50 °C it's 593 A, at 60 °C it's 557 A, at 70 °C it's 520 A. That's high-end fault current handling — typical for large transformer secondaries or industrial mains. The trip indicator and undervoltage release are already built in. The auxiliary switch configuration — two aux switches plus a trip alarm and an electrical alarm — gives you remote status for both normal position and fault events without adding separate modules.

Frequently asked questions

Where can I buy 3VA2463-7HL32-0BL0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

What are the key ratings for this MCCB?

630 A continuous at 40 °C, 3-pole, with breaking capacities of 330 kA at 240 V, 242 kA at 415 V, and 242 kA at 440 V. It includes an undervoltage release and two auxiliary switches plus trip and electrical alarm switches.

What is the physical size of this breaker?

248 mm tall, 138 mm wide, 110 mm deep — standard MCCB footprint for a 630 A frame.

Does this breaker include a shunt trip or undervoltage release?

It includes an undervoltage release (UVR) as standard. No voltage trigger (shunt trip) is fitted on this variant.

MPN
3VA2463-7HL32-0BL0