Skip to main content
Siemens 3VA2463-7HL32-0CL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-7HL32-0CL0 SENTRON MCCB, 630 A, 3-Pole, 110

MPN3VA2463-7HL32-0CL0

Siemens SENTRON 3VA2463-7HL32-0CL0, molded case circuit breaker, 3-pole, 630 A continuous at 40 °C, breaking capacity 330 kA at 240 V, line protection design, undervoltage release, 110 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-7HL32-0CL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2463-7HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2463-7HL32-0CL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V9 kA
Power loss, max.164.5 W
3VA2463-7HL32-0CL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2463-7HL32-0CL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-7HL32-0CL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2463-7HL32-0CL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-7HL32-0CL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens SENTRON 3VA2463-7HL32-0CL0 is a 3-pole molded case circuit breaker (MCCB) rated for 630 A continuous current at 40 °C, with a derating curve that drops to 520 A at 70 °C — so if your panel ambient runs hot, size the load at the 70 °C figure, not the nameplate 630 A. Breaking capacity hits 330 kA at 240 V and stays at 242 kA through 440 V, then drops to 187 kA at 500 V and 9 kA at 690 V — the 690 V number is the weak leg; if your system runs at that voltage, verify the fault current doesn't exceed 9 kA or step up to a higher-rated frame. This is a line-protection design (not motor-protection), so it's intended for feeder and distribution duty, not direct motor starting — pair it with a contactor and overload for motor branch circuits.

Integration — fits and wiring

The basic switch is order code 3VA2463-7HL32-0AA0 — if you need the bare breaker without auxiliaries, that's the variant to source.

Thermal and environmental limits

Maximum power loss is 164.5 W — account for this heat in your enclosure ventilation calculation, especially when multiple breakers are ganged.

Frequently asked questions

What is the depth of this breaker?

110 mm (4.33 in).

MPN