Siemens 3VA2463-7HL32-0DL0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA2463-7HL32-0DL0 MCCB, 630 A, 3-Pole, Line Protect

MPN3VA2463-7HL32-0DL0

SENTRON 3VA2463-7HL32-0DL0, molded case circuit breaker, 3-pole, 630 A continuous, line protection, 330 kA at 240 V, undervoltage release, 110 x 138 x 248 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-7HL32-0DL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2463-7HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2463-7HL32-0DL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V9 kA
Power loss, max.164.5 W
3VA2463-7HL32-0DL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2463-7HL32-0DL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-7HL32-0DL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2463-7HL32-0DL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-7HL32-0DL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Its interrupting capacity hits 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 9 kA at 690 V — so it handles high-fault service entrances and downstream sub-feeders without cascading upstream.

The 630 A rating holds at 40 °C ambient; above that, the continuous current derates stepwise — 612 A at 45 °C, 593 A at 50 °C, 575 A at 55 °C, 557 A at 60 °C, 538 A at 65 °C, and 520 A at 70 °C. The 110 mm depth and 138 mm width fit standard MCCB panel cutouts; the 248 mm height clears most deadfront covers.

Built-in auxiliary and undervoltage release

The basic switch base is order code 3VA2463-7HL32-0AA0, so the auxiliary configuration is pre-assembled, not field-added.

Frequently asked questions

How do I get current pricing and availability for 3VA2463-7HL32-0DL0?

Pricing and availability are confirmed at quote time against an RFQ through independent distribution. Submit an RFQ for a current quote and lead-time estimate.

What is the closest functional second-source to 3VA2463-7HL32-0DL0?

The evidence lists 5SQ2370-2YA05, 5SQ2370-2YA04, and 5SQ2370-2YA01 as peer MPNs, but no official cross-reference or drop-in replacement is documented. Panel fit and wiring should be verified against the specific peer before substitution.

Will 3VA2463-7HL32-0DL0 drop into a panel specified around 5SQ2370-2YA05 without rewiring?

No official cross-reference exists between 3VA2463-7HL32-0DL0 and 5SQ2370-2YA05. Panel fit, mounting pattern, and terminal spacing must be verified against the specific peer before assuming a drop-in replacement.

What compliance documentation does this brand provide for 3VA2463-7HL32-0DL0?

The evidence does not list specific compliance documents (RoHS, REACH, UL, IEC) for this order code. Standard SENTRON MCCB documentation typically includes UL 489 and IEC 60947-2 declarations; confirm with the supplier at quote time.

MPN
3VA2463-7HL32-0DL0