Skip to main content
Siemens 3VA2463-7HN32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2463-7HN32-0AD0 MCCB, 630 A, 3-pole, ETU3

MPN3VA2463-7HN32-0AD0

Siemens SENTRON 3VA2463-7HN32-0AD0, molded case circuit breaker, 630 A at 40 °C, 3-pole, ETU350 overcurrent release, line protection version, 3 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2463-7HN32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2463-7HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2463-7HN32-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V9 kA
Power loss, max.162 W

Protection & Trip Unit

3VA2463-7HN32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout

Construction & Connection

3VA2463-7HN32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2463-7HN32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2463-7HN32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2463-7HN32-0AD0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

630 A MCCB with ETU350 — what the ratings mean for fit

The Siemens SENTRON 3VA2463-7HN32-0AD0 is a 3-pole molded case circuit breaker (MCCB) rated at 630 A at 40 °C, with a continuous current derating curve down to 520 A at 70 °C — so the actual thermal limit depends on your enclosure ambient, not just the nameplate. It carries the ETU350 electronic overcurrent release, which gives you adjustable long-time, short-time, instantaneous, and ground-fault protection curves; this is the line protection variant, meaning it's optimized for feeder and main breaker duty rather than motor branch circuit protection. Breaking capacity spans 330 kA at 240 V down to 9 kA at 690 V — at 415/440 V it still holds 242 kA, which covers most industrial distribution panels with high fault current potential. Rated insulation voltage is 800 V, so it's suitable for 690 V systems with margin. Three auxiliary switches (HQ type) are built in, giving you status feedback for the open/closed/tripped positions without needing add-on modules. Power loss at rated current is 162 W — factor that into your panel thermal budget.

Panel integration notes

Dimensions are 248 mm height, 138 mm width, 110 mm depth — a standard SENTRON 3VA frame size that mounts on a DIN rail or directly to a backplate via the supplied mounting brackets. The 3-pole footprint leaves room for side-mounted accessories like rotary handles or shunt trips, though this variant ships without undervoltage release or communication module. Operating temperature range is -25 °C to 70 °C, storage from -40 °C to 80 °C — suitable for unheated electrical rooms or outdoor enclosures in moderate climates.

Frequently asked questions

What is the breaking capacity of 3VA2463-7HN32-0AD0 at 415 V?

At 415 V the breaking capacity is 242 kA, which is the same rating as at 440 V. At 240 V it reaches 330 kA, and at 690 V it drops to 9 kA.

What overcurrent release does 3VA2463-7HN32-0AD0 use?

It uses the ETU350 electronic trip unit, which provides adjustable long-time, short-time, instantaneous, and ground-fault protection settings. This is the line protection version.

Where can I buy 3VA2463-7HN32-0AD0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent industrial distribution. Availability and current pricing are confirmed at the time of quotation.

MPN
3VA2463-7HN32-0AD0