Skip to main content
Siemens 3VA2463-8HK32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-8HK32-0AA0 SENTRON MCCB, 630 A, 3-Pole, ETU3

MPN3VA2463-8HK32-0AA0
Active

Siemens SENTRON 3VA2463-8HK32-0AA0, molded case circuit breaker, 3-pole, 630 A continuous, ETU340 electronic trip unit, 440 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-8HK32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2463-8HK32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.162 W
3VA2463-8HK32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU340
Overcurrent protection functionELISA LI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2463-8HK32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-8HK32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2463-8HK32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-8HK32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

630 A MCCB with ETU340 — selectivity and SCCR headroom

The Siemens SENTRON 3VA2463-8HK32-0AA0 is a 3-pole molded case circuit breaker rated for 630 A continuous at 40 °C, with an electronic ETU340 overcurrent release. Its interrupting capacity reaches 440 kA at 240 V, 330 kA at 415 V, and 52.5 kA at 690 V — figures that give the panel designer headroom for high-fault installations where upstream coordination demands a robust SCCR. The 630 A frame means this breaker handles main feeder or large motor-circuit duty in switchboards and distribution panels.

The continuous current derates from 630 A at 40 °C down to 520 A at 70 °C — a curve the panel builder must account for when calculating fill factor and ventilation. Maximum power loss is 162 W, which drives heat dissipation requirements inside the enclosure.

Frequently asked questions

What overcurrent release does 3VA2463-8HK32-0AA0 use?

The ETU340 electronic trip unit, which provides adjustable long-time, short-time, instantaneous, and ground-fault protection curves.

MPN
3VA2463-8HK32-0AA0