Skip to main content
Siemens 3VA2463-8HN42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-8HN42-0AA0 MCCB, 630A, 150kA @ 415V

MPN3VA2463-8HN42-0AA0
Active

Siemens 3VA2 IEC Molded Case Circuit Breaker, Frame 630, breaking capacity class L, Icu=150 kA @ 415 V, 4-pole, line protection ETU350 LSI, In=630 A, overload protection Ir=250...630 A.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Specifications

3VA2463-8HN42-0AA0 — Specifications
ParameterValue
Group codeP360
Product group5374
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
Series3VA Molded Case Circuit Breakers up to 1600 A, IEC
Export control regulationsAL : N / ECCN : N
Compliance with the substance restrictions according to RoHS directiveSince: 01-04-14

Product details

Panel integration and mounting

The 3VA2 Frame 630 breaker mounts in a standard switchboard or panel enclosure via the included nut keeper kit — no special adapter plate required. The packaging dimensions (265 x 210 x 170 mm) give a rough envelope for panel layout; verify the cutout and bus bar spacing against the Siemens mounting template for this frame size.

Compliance and regulatory documentation

RoHS compliant since 01-04-14. REACH Article 33 duty to inform: the product contains Lead (CAS 7439-92-1) above 0.1% w/w in the candidate list. Export control: AL N / ECCN N — no special license required for standard industrial use.

Frequently asked questions

Where can I buy 3VA2463-8HN42-0AA0?

This MCCB is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and delivery requirements.

What is the breaking capacity of this breaker?

The 3VA2463-8HN42-0AA0 has a breaking capacity class L with Icu = 150 kA at 415 V AC. This is the maximum fault current it can safely interrupt under IEC 60947-2 test conditions.

What protection settings does the ETU350 trip unit offer?

The ETU350 provides LSI protection: long-time pickup (Ir) adjustable 250 A to 630 A, short-time pickup (Isd) adjustable 1.5x to 9x Ir, and instantaneous (Ii) fixed at 9x In. Neutral protection is selectable OFF, 50%, or 100% of phase current.

What compliance documentation is available for this part?

RoHS compliance dated 01-04-14. REACH Article 33 notice for Lead content above 0.1% w/w. Export control classification AL N / ECCN N. No UL or CSA listing is stated in the available documentation.