Siemens 3VA2510-5HL32-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-5HL32-0BC0 SENTRON MCCB, 1000 A, 187 kA at 2

MPN3VA2510-5HL32-0BC0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2510-5HL32-0BC0, 3-pole, 1000 A, ETU320 trip unit, 187 kA at 240 V, 121 kA at 415 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2510-5HL32-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.#BEZUG!
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2510-5HL32-0BC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C1 000 A
Current at 60 °C955 A
Current at 65 °C885 A
Current at 70 °C815 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.332.5 W
3VA2510-5HL32-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA2510-5HL32-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2510-5HL32-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA2510-5HL32-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2510-5HL32-0BC0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.27 in
Depth (in)4.72 in

Product details

The interrupting ratings are the headline: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 52.5 kA at 690 V. The ETU320 trip unit gives you adjustable long-time, short-time, and instantaneous protection curves, plus an undervoltage release is fitted as standard. No trip indicator on the front, so fault diagnostics rely on the release's own flag or a connected indication.

At 60 °C it derates to 955 A, at 65 °C to 885 A, and at 70 °C to 815 A. Physical footprint: 210 mm wide, 320 mm tall, 120 mm deep. That's a 3-pole frame in the 3VA2 platform — it bolts into a standard MCCB mounting pattern, not a DIN rail.

Frequently asked questions

Does this breaker have a trip indicator or communication capability?

No trip indicator on the front, and no communication function. It does have an undervoltage release and two auxiliary switches (HQ type) for status feedback.

MPN