Siemens 3VA2510-5HL32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-5HL32-0HC0 SENTRON MCCB, 1000 A, 187 kA at 2

MPN3VA2510-5HL32-0HC0

Siemens SENTRON 3VA2510-5HL32-0HC0, molded case circuit breaker, 3-pole, 1000 A rated continuous current, 187 kA interrupting at 240 V, ETU320 electronic trip unit, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2510-5HL32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2510-5HL32-0HC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C1 000 A
Current at 60 °C955 A
Current at 65 °C885 A
Current at 70 °C815 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.123 W
3VA2510-5HL32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2510-5HL32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2510-5HL32-0HC0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2510-5HL32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2510-5HL32-0HC0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

The Siemens 3VA2510-5HL32-0HC0 is a SENTRON molded case circuit breaker sized for 1000 A continuous current across three poles, with an interrupting capacity of 187 kA at 240 V and 121 kA at 415 V — enough to clear high-fault industrial feeders without cascading upstream. It carries the ETU320 electronic trip unit, adjustable from 400 A to 1000 A for the long-time pickup (Ir) and 1500 A to 10 000 A for instantaneous (Ii), so you can tune it to the cable and load without swapping the breaker.

Full 1000 A rating holds through 55 °C ambient; at 60 °C it derates to 955 A, at 65 °C to 885 A, and at 70 °C to 815 A. Plan your enclosure cooling if the breaker sits near other heat sources in a sealed cabinet. Verify the gland-plate cutout and bus-bar spacing before panel layout.

Frequently asked questions

What is the interrupting capacity of 3VA2510-5HL32-0HC0 at 415 V?

It is rated 121 kA at 415 V, with 187 kA at 240 V and 53 kA at 690 V. This covers most industrial distribution fault levels without needing a current-limiting upstream breaker.

What trip unit does this MCCB use?

The ETU320 electronic trip unit, adjustable Ir from 400 A to 1000 A and Ii from 1500 A to 10 000 A. Long-time delay tr is adjustable from 0.5 s to 17 s.

Where can I buy 3VA2510-5HL32-0HC0?

This part is sourced to order against an RFQ through independent distribution channels. Submit a request for current pricing and availability; lead time is confirmed at quote time.

MPN
3VA2510-5HL32-0HC0