Skip to main content
Siemens 3VA2510-5HL32-0KF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-5HL32-0KF0 Circuit Breaker, 1000A, 55kA @ 41

MPN3VA2510-5HL32-0KF0

Siemens 3VA2 IEC frame 1000 circuit breaker, 3-pole, breaking capacity class M, Icu=55kA @ 415V, ETU320 LI trip unit, In=1000A, shunt trip left 208-277V AC / 220-250V DC, 1 auxiliary switch, nut keeper kit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The 3VA2510-5HL32-0KF0 is a 3-pole IEC frame 1000 circuit breaker from the Siemens 3VA2 series, rated for line protection with an ETU320 electronic trip unit offering LI (long-time and instantaneous) protection. For a 1000 A frame, that is a high-interrupt rating (class M) suited to main or large feeder breakers in industrial switchboards where the transformer or utility supply can deliver substantial short-circuit energy. The LI trip curve means overload protection (Ir) is adjustable from 400 A to 1000 A, and instantaneous short-circuit pickup (Ii) is adjustable from 1.5 to 10 times In (1500–10,000 A). This adjustability lets the breaker coordinate selectively with downstream devices — a critical feature when you need a fault on a branch to clear before the main trips, keeping the rest of the plant live.

Built-in accessories and deployment context

This order code ships with a shunt trip (left-mounted) rated 208–277 V AC 50/60 Hz and 220–250 V DC, plus one auxiliary switch. The 3VA2 frame is designed for fixed or plug-in mounting in Siemens switchgear assemblies or standard distribution panels. At 1000 A, this breaker is typically bolted to busbars in a main switchboard or large MCC bucket, not snapped onto a DIN rail. Plan for panel cutout dimensions per the 3VA2 frame 1000 template — the frame size dictates the mounting hole pattern and busbar spacing.

Because this is a high-current frame breaker with specific accessories (shunt trip, aux switch), lead times can vary with the factory backlog; a sourcing inquiry is the fastest way to lock in delivery for a project schedule.

Frequently asked questions

What is the breaking capacity of this breaker?

The 3VA2510-5HL32-0KF0 has a rated ultimate breaking capacity (Icu) of 55 kA at 415 V AC, placing it in breaking capacity class M for the 3VA2 IEC frame 1000 series.

What accessories are included with this order code?

This order code includes a shunt trip (left-mounted, rated 208–277 V AC / 220–250 V DC), one auxiliary switch, and a nut keeper kit for bus-bar connections.

How do I get current pricing and availability for 3VA2510-5HL32-0KF0?

Current pricing and availability are confirmed at quote time against an RFQ through independent distribution channels. Submit a sourcing request with your target quantity and delivery timeline.

MPN
3VA2510-5HL32-0KF0