Skip to main content
Siemens 3VA2510-5HN32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-5HN32-0AD0 SENTRON MCCB, 1000 A, 187 kA

MPN3VA2510-5HN32-0AD0

Siemens SENTRON 3VA2, molded case circuit breaker, 3-pole, 1000 A, 187 kA at 240 V, ETU350 electronic trip unit, line protection version.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2510-5HN32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2510-5HN32-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C1 000 A
Current at 60 °C955 A
Current at 65 °C885 A
Current at 70 °C815 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.123 W
3VA2510-5HN32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2510-5HN32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2510-5HN32-0AD0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2510-5HN32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2510-5HN32-0AD0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

The Siemens 3VA2510-5HN32-0AD0 is a SENTRON 3VA2 molded case circuit breaker in the line protection version, rated 1000 A continuous current (Iu) across 40 °C to 55 °C ambient, derating to 955 A at 60 °C and 815 A at 70 °C. Breaking capacity runs 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V — figures that cover most industrial fault-current scenarios without needing a current-limiting upstream device. The ETU350 electronic trip unit gives adjustable long-time pickup (Ir) from 0.5 to 1.0 × Iu, short-time delay (tsd) from 0.04 to 0.4 s, and instantaneous pickup (Ii) up to 10 000 A. That range suits feeder protection where coordination with downstream breakers matters.

Dimensions are 210 mm wide, 320 mm high, 120 mm deep. Front protection is IP40.

Frequently asked questions

What trip unit does the 3VA2510-5HN32-0AD0 use?

The ETU350 electronic trip unit with adjustable long-time, short-time, and instantaneous settings.

MPN
3VA2510-5HN32-0AD0