Skip to main content
Siemens 3VA2510-5HN32-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2510-5HN32-0CC0 MCCB, 1000 A, 187 kA at 2

MPN3VA2510-5HN32-0CC0

Siemens SENTRON series, molded case circuit breaker, 3VA2510-5HN32-0CC0, 3-pole, 1000 A, 187 kA at 240 V, ETU350 release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2510-5HN32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2510-5HN32-0CC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C1 000 A
Current at 60 °C955 A
Current at 65 °C885 A
Current at 70 °C815 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.123 W
3VA2510-5HN32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2510-5HN32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2510-5HN32-0CC0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2510-5HN32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2510-5HN32-0CC0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

What this MCCB does and the ratings that matter

The Siemens SENTRON 3VA2510-5HN32-0CC0 is a 3-pole molded case circuit breaker rated for line protection, carrying a continuous current of 1 000 A at 40 °C and an insulation voltage of 800 V. The ETU350 electronic trip unit gives you adjustable overload and short-circuit protection: Ir from 400 A up to 1 000 A, and Isd (short-time delay) adjustable between 0.04 s and 0.4 s. The breaking capacity is 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V — enough to handle high-fault utility feeds or large transformer secondaries without cascading upstream. At 60 °C ambient the breaker derates to 955 A, at 65 °C to 885 A, and at 70 °C to 815 A — so if your panel runs hot, size the load accordingly.

The 3VA2510-5HN32-0CC0 measures 210 mm wide, 320 mm high, and 120 mm deep. The 210 mm width (8.3 in) determines the mounting footprint; plan for a 3-pole breaker cutout.

What the ETU350 release gives you

Long-time pickup Ir is adjustable from 0.4 to 1.0 × In (400–1 000 A), with time delay tr from 0.5 s to 17 s at 6× Ir. Short-time pickup Isd is adjustable from 1.5 to 10 × Ir (1 500–10 000 A), with delay tsd from 0.04 s to 0.4 s. Instantaneous pickup Ii is fixed at 10 000 A. This selectivity range lets you coordinate with downstream breakers without nuisance tripping on motor inrush.

Frequently asked questions

Who supplies 3VA2510-5HN32-0CC0 and how is it quoted for volume purchases?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 3VA2510-5HN32-0CC0's listed depth?

The listed depth is 120 mm, which fits standard 200 mm deep enclosures with room for wiring gutters.

What is 3VA2510-5HN32-0CC0's listed width?

The listed width is 210 mm (8.3 in), determining the mounting cutout for this 3-pole breaker.

What compliance documentation does this brand provide for 3VA2510-5HN32-0CC0?

The SENTRON brand typically provides RoHS, REACH, UL, and IEC compliance documentation. Specific declarations are available upon request with the order.

MPN
3VA2510-5HN32-0CC0