Skip to main content
Siemens 3VA2510-5HN32-0HL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-5HN32-0HL0 SENTRON MCCB, 1000 A, 3-Pole, ETU

MPN3VA2510-5HN32-0HL0

Siemens SENTRON 3VA2510-5HN32-0HL0, molded case circuit breaker, line protection, 3-pole, 1000 A rated continuous current, ETU350 electronic trip unit, 187 kA at 240 V, 121 kA at 415 V, 53 kA at 690 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2510-5HN32-0HL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2510-5HN32-0HL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C1 000 A
Current at 60 °C955 A
Current at 65 °C885 A
Current at 70 °C815 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.123 W
3VA2510-5HN32-0HL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2510-5HN32-0HL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2510-5HN32-0HL0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2510-5HN32-0HL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2510-5HN32-0HL0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

The Siemens 3VA2510-5HN32-0HL0 is a SENTRON molded case circuit breaker rated for line protection, 3-pole, with a continuous current rating of 1000 A at 40 °C through 55 °C — it holds full ampacity across that band, then derates to 955 A at 60 °C, 885 A at 65 °C, and 815 A at 70 °C. That thermal profile means you can run it in a warm enclosure without stepping down the frame size, as long as the ambient stays under 55 °C. Breaking capacity is 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V — that's high enough for most industrial main or feeder duty where fault current runs high. The ETU350 electronic trip unit gives you adjustable long-time pickup (Ir) from 0.5 to 1.0 × In, short-time pickup and delay, and instantaneous pickup (Ii) up to 10 000 A. That's a lot of coordination range for selective tripping downstream. Physical footprint: 210 mm wide, 320 mm tall, 120 mm deep.

Mounts in a standard MCCB footprint — 210 mm wide, 320 mm tall, 120 mm deep. That is a 3-pole frame that fits most switchboard or panelboard cutouts.

MPN
3VA2510-5HN32-0HL0