Skip to main content
Siemens 3VA2510-5HN32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-5HN32-0JC0 SENTRON MCCB, 1000 A, 3-Pole, ETU

MPN3VA2510-5HN32-0JC0

Siemens SENTRON 3VA2510-5HN32-0JC0, molded case circuit breaker, line protection, 3-pole, 1000 A, ETU350 electronic trip unit, 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2510-5HN32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2510-5HN32-0JC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C1 000 A
Current at 60 °C955 A
Current at 65 °C885 A
Current at 70 °C815 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.123 W
3VA2510-5HN32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2510-5HN32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2510-5HN32-0JC0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2510-5HN32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2510-5HN32-0JC0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

What the 1000 A continuous rating means for your feeder

The ETU350 electronic trip unit lets you dial the long-time pickup (Ir) from 0.5 to 1.0 × Iu, so you set it to match the actual load, not just the breaker frame. At 415 V it interrupts 121 kA symmetrical; at 240 V that jumps to 187 kA. Those numbers tell you this breaker clears a bolted fault upstream of a large motor control center or a transformer secondary without the arc re-striking — it's sized for high-fault installations, not branch circuits.

Derating and thermal reality in the panel

This breaker holds its full 1000 A rating up to 55 °C ambient. At 60 °C it derates to 955 A, at 65 °C to 885 A, and at 70 °C to 815 A. The frame measures 320 mm high × 210 mm wide × 120 mm deep. That's a standard SENTRON 3VA2 drawout cassette footprint; it fits the same cubicle as other 3VA2 breakers in the line.

Frequently asked questions

What is the interrupting rating of 3VA2510-5HN32-0JC0 at 415 V?

121 kA symmetrical at 415 V. At 240 V it's 187 kA, and at 690 V it's 53 kA.

What trip unit does this MCCB use?

The ETU350 electronic overcurrent release. It offers adjustable long-time pickup (Ir) from 0.5 to 1.0 × Iu, short-time delay (tsd) from 0.04 to 0.4 s, and instantaneous pickup (Ii) up to 10 000 A.

Where can I buy 3VA2510-5HN32-0JC0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
3VA2510-5HN32-0JC0