Siemens 3VA2510-5JP42-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-5JP42-0KA0 1000A Circuit Breaker, 55kA @ 415

MPN3VA2510-5JP42-0KA0

Siemens 3VA2 IEC frame 1000, breaking capacity class M, Icu=55kA @ 415V, 4-pole, line protection ETU550, LSI, In=1000A, overload Ir=400-1000A, shunt trip left 208-277V AC/220-250V DC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA2510-5JP42-0KA0 is a 4-pole IEC frame 1000 circuit breaker with a 55 kA interrupting capacity at 415 V — breaking capacity class M. It carries the ETU550 electronic trip unit configured for LSI protection (long-time, short-time, instantaneous) with a rated continuous current In of 1000 A and an adjustable overload pickup Ir from 400 A to 1000 A. This is a line-protection breaker, not a motor-circuit protector; the LSI curve suits distribution feeders and large loads where selective coordination matters.

In a panel with a transformer secondary or a large bus feeding a 1000 A feeder, that rating gives headroom for most industrial installations without cascading upstream. The ETU550 LSI trip allows coordination: Isd adjustable 0.6–10× In covers short-time delay for selectivity with downstream breakers; Ii adjustable 1.5–10× In sets the instantaneous pickup. Neutral protection is adjustable (OFF up to 100 % of phase current). The shunt trip accessory means this breaker can be remotely tripped by a safety circuit or emergency-stop system — the left-side coil draws from 208–277 V AC or 220–250 V DC, so it integrates directly into common control voltages without an interposing relay.

Deployment context

This breaker mounts in a standard IEC switchboard or distribution panel — it is a fixed (not drawout) frame 1000 unit, so plan for busbar connection and sufficient enclosure volume for cable bending radius. The nut keeper kit (included per the description) secures the terminals against vibration in high-ambient environments like cement plants or steel mills. The electronic trip unit is field-configurable; the rotary dials for Ir, Isd, Ii, and neutral protection are accessible through the cover without removing the breaker.

Frequently asked questions

What is the breaking capacity of this breaker?

It has an Icu of 55 kA at 415 V, which is breaking capacity class M under IEC 60947-2. This is the maximum fault current it can safely clear once.

What trip unit and protection functions does it have?

It uses the ETU550 electronic trip unit with LSI protection: long-time (overload Ir adjustable 400–1000 A), short-time (Isd adjustable 0.6–10× In), and instantaneous (Ii adjustable 1.5–10× In). Neutral protection is adjustable from OFF to 100 %.

What voltage does the shunt trip require?

The integrated left-side shunt trip operates on 208–277 V AC 50/60 Hz or 220–250 V DC.