Siemens 3VA2510-5KQ32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-5KQ32-0AJ0 SENTRON MCCB, 1000 A, 187 kA at 2

MPN3VA2510-5KQ32-0AJ0

Siemens SENTRON 3VA2510-5KQ32-0AJ0, molded case circuit breaker, 3-pole, line protection, 1000 A rated continuous current, 187 kA at 240 V, 121 kA at 415 V, 53 kA at 690 V, ETU860 electronic trip unit, communication function.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2510-5KQ32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2510-5KQ32-0AJ0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C1 000 A
Current at 60 °C955 A
Current at 65 °C885 A
Current at 70 °C815 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.123 W
3VA2510-5KQ32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
3VA2510-5KQ32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2510-5KQ32-0AJ0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
3VA2510-5KQ32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2510-5KQ32-0AJ0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

The Siemens 3VA2510-5KQ32-0AJ0 is a 3-pole SENTRON molded case circuit breaker rated for 1000 A continuous current at 40 °C through 55 °C, with a slight derating curve above that — 955 A at 60 °C, 885 A at 65 °C, 815 A at 70 °C. That means you can run it at full nameplate in most ventilated enclosures; only push the derating if the panel ambient climbs above 55 °C. Breaking capacity is the headline number for a main breaker: 187 kA at 240 V, 121 kA at 415 V, 53 kA at 690 V. Those are high-interrupting ratings — enough for transformer-secondaries or large motor-control centers where fault current can hit 100 kA+. The 415 V figure (121 kA) is the one most panel builders will check against their utility transformer impedance; it clears a 100 kA fault with headroom. The ETU860 electronic trip unit gives you adjustable long-time (tr 0.5–25 s), short-time (tsd 0.05–0.5 s), and instantaneous pickup (Ir adjustable up to 1000 A). That means you can shape the curve for selective coordination downstream — a real advantage over fixed-trip thermal-magnetic breakers when you need to keep a fault from taking out the whole MCC.

Mounting and integration — fits a standard MCCB footprint

Dimensions: 320 mm high, 210 mm wide, 120 mm deep. IP40 on the front. Rated insulation voltage 800 V. Maximum power loss 123 W.

Frequently asked questions

Does 3VA2510-5KQ32-0AJ0 support communication?

Yes, it has a communication function — fieldbus-ready for integration with a PLC or SCADA system.