Skip to main content
Siemens 3VA2510-5KQ32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-5KQ32-0DH0 SENTRON MCCB, 1000 A, 187 kA at 2

MPN3VA2510-5KQ32-0DH0

Siemens SENTRON 3VA2510-5KQ32-0DH0, 3-pole molded case circuit breaker, line protection, 1000 A rated continuous current, 187 kA at 240 V, 121 kA at 415 V, 53 kA at 690 V, ETU860 electronic trip unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2510-5KQ32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2510-5KQ32-0DH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C1 000 A
Current at 60 °C955 A
Current at 65 °C885 A
Current at 70 °C815 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.123 W
3VA2510-5KQ32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
3VA2510-5KQ32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2510-5KQ32-0DH0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
3VA2510-5KQ32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2510-5KQ32-0DH0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

The Siemens SENTRON 3VA2510-5KQ32-0DH0 is a 3-pole molded case circuit breaker rated for 1000 A continuous current (Iu) at 40–55 °C without derating, and 955 A at 60 °C, 885 A at 65 °C, 815 A at 70 °C. Its breaking capacity reaches 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V — figures that tell you it can interrupt high-fault currents on large distribution transformers or bus risers without cascading upstream. The ETU860 electronic trip unit gives you adjustable long-time delay (tr 0.5–25 s) and short-time delay (tsd 0.05–0.5 s), plus ground-fault monitoring via summation current sensing on the line conductors.

The breaker measures 210 mm wide, 320 mm high, and 120 mm deep — a 3-pole frame that fits standard SENTRON mounting plates. Front protection is IP40, so it's suited for enclosed switchgear where tools or fingers won't reach live parts. Communication function is built in, meaning it can report status and trip events to a higher-level system without an external module.

Frequently asked questions

Where can I buy 3VA2510-5KQ32-0DH0 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

What is the depth of 3VA2510-5KQ32-0DH0?

The depth is 120 mm, with a width of 210 mm and height of 320 mm.

Will 3VA2510-5KQ32-0DH0 drop into a panel specified around 5SQ2370-2YA05?

The 5SQ2370-2YA series are SENTRON 3VA breakers in the same 1000 A frame class, so the mounting hole pattern and bus-bar spacing are identical. The trip unit and communication options may differ — verify the ETU860 settings against your coordination study before swapping.

MPN
3VA2510-5KQ32-0DH0