Siemens 3VA2510-5KQ42-0DJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-5KQ42-0DJ0 Circuit Breaker, 1000A, 55kA @ 41

MPN3VA2510-5KQ42-0DJ0

Siemens 3VA2 IEC frame 1000 circuit breaker, breaking capacity class M, Icu=55kA @ 415V, 4-pole, ETU860 LSIG protection, In=1000A, with undervoltage release 208-230 V AC 50/60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What this 3VA2 breaker carries

The Siemens 3VA2510-5KQ42-0DJ0 is a 4-pole IEC frame 1000 circuit breaker in breaking capacity class M, rated Icu=55kA at 415 V AC. It ships with an ETU860 electronic trip unit configured for LSIG protection — long-time, short-time, instantaneous, and ground-fault — with an In=1000 A continuous current rating and overload protection adjustable from Ir=400 A up to 1000 A. Short-circuit protection ranges Isd=0.6 to 10× In and Ii=1.5 to 10× In. The neutral conductor protection is adjustable (OFF up to 100%), and ground-fault protection can be switched off with Ig adjustable from 0.2 to 1× In and a time delay tg=0.05 to 0.8 s. An integrated undervoltage release rated 208-230 V AC 50/60 Hz is included as an accessory for the 3VA1 platform.

The ETU860 LSIG trip unit gives selective coordination capability: the adjustable short-time pickup and delay (Isd, tg) let you set the breaker to ride through downstream faults, clearing only the faulted branch. The ground-fault element (Ig adjustable 0.2–1× In, tg 0.05–0.8 s) is switchable, useful for systems where GFP is not required or conflicts with upstream coordination. The undervoltage release (208-230 V AC) provides automatic tripping on loss of control voltage, a common requirement for safety circuits in conveyor and process lines.

Frequently asked questions

What is the breaking capacity of this breaker?

The breaking capacity is Icu=55 kA at 415 V AC, class M on the IEC frame 1000 platform.

What protection functions does the ETU860 trip unit provide?

The ETU860 provides LSIG protection: long-time (L), short-time (S), instantaneous (I), and ground-fault (G) with adjustable settings for each element.

Where can I buy 3VA2510-5KQ42-0DJ0?

This part is sourced and quoted to order against an RFQ through independent distribution, with availability and current pricing confirmed at quote time.

MPN
3VA2510-5KQ42-0DJ0