Skip to main content
Siemens 3VA2510-6HL32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-6HL32-0DH0 Circuit Breaker, 1000A, 85kA @ 41

MPN3VA2510-6HL32-0DH0

Siemens 3VA2 IEC frame 1000, 3-pole circuit breaker, breaking capacity class H, Icu=85kA @ 415V, ETU320 LI trip unit, In=1000A, Ir=400A...1000A, Ii=1.5...10 x In, with undervoltage release 208-230 V AC 50/60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What this 3VA2 breaker carries

The Siemens 3VA2510-6HL32-0DH0 is a 3-pole IEC circuit breaker on the 3VA2 frame, rated 1000 A continuous with a high breaking capacity class H — Icu of 85 kA at 415 V AC. The ETU320 LI trip unit provides adjustable overload protection (Ir = 400 A to 1000 A) and short-circuit protection (Ii = 1.5 to 10 x In). For a 1000 A frame, the 1.5x minimum setting lets you dial in a tight magnetic pickup for cable protection; the 10x max covers motor-starting inrush on a large VFD feed.

The ETU320 is a basic LI (long-time + instantaneous) electronic trip — no ground-fault or zone-selective interlocking, so keep that in mind if the spec requires LSIG or ZSI coordination. The undervoltage release is a factory-fitted accessory; verify the control voltage (208-230 V AC) matches the panel's control transformer tap before energizing. The nut keeper kit retains the terminal hardware during high-vibration environments like genset paralleling switchgear.

Frequently asked questions

What is the breaking capacity of this breaker?

It has an Icu of 85 kA at 415 V AC, which is the class H breaking capacity on the 3VA2 IEC frame. That rating covers most main-distribution fault levels without needing current-limiting fuses.

What trip unit does this breaker use?

The ETU320 LI electronic trip unit with adjustable overload protection Ir = 400 A to 1000 A and short-circuit pickup Ii = 1.5 to 10 x In. It is a basic LI (long-time and instantaneous) unit — no ground-fault or short-time delay.

Does this breaker include an undervoltage release?

Yes, it includes an undervoltage release rated 208-230 V AC, 50/60 Hz, factory-fitted. The UVR will trip the breaker when the control voltage drops below the dropout threshold.

Where can I buy 3VA2510-6HL32-0DH0?

This part is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time.

MPN
3VA2510-6HL32-0DH0