Siemens 3VA2510-6HM32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-6HM32-0AA0 SENTRON MCCB, 1000 A, 242 kA at 2

MPN3VA2510-6HM32-0AA0
Active

Siemens SENTRON 3VA2, molded case circuit breaker, 3-pole, 1000 A, 242 kA at 240 V, ETU330 electronic trip unit, line protection version.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2510-6HM32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2510-6HM32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C1 000 A
Current at 60 °C955 A
Current at 65 °C885 A
Current at 70 °C815 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V74 kA
Power loss, max.330 W
3VA2510-6HM32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
3VA2510-6HM32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2510-6HM32-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Auxiliary CO contacts0
3VA2510-6HM32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2510-6HM32-0AA0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in
Depth (in)4.7 in

Product details

The Siemens 3VA2510-6HM32-0AA0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) in the line protection version, rated for 1000 A continuous current at 40 °C with a 3-pole configuration.

At 60 °C it drops to 955 A, at 70 °C to 815 A. That thermal curve matters when the breaker shares a crowded panel with other heat sources; the 330 W maximum power loss is the heat you need to vent. The ETU330 electronic trip unit gives adjustable long-time pickup (Ir) from 0.5 to 1.0 × Iu and adjustable long-time delay (tr) from 0.5 to 17 seconds. That lets you coordinate selectively with downstream breakers — critical for keeping a fault from taking out the whole bus.

Front protection is IP40, so it's suited for enclosed distribution boards where tools and fingers stay out. No communication function onboard; this is a straight line-protection breaker with no integrated metering or Modbus.

Frequently asked questions

Does the 3VA2510-6HM32-0AA0 have communication capability?

No. The communication function is listed as 'No' — this is a standalone line-protection breaker with no onboard metering, Modbus, or network interface.

MPN
3VA2510-6HM32-0AA0