Siemens SENTRON 3VA2510-6HN32-0AF0, molded case circuit breaker, 3-pole, 1000 A, ETU350 electronic trip unit, line protection, 242 kA at 240 V, 187 kA at 415 V, 74 kA at 690 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2510-6HN32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2510-6HN32-0AF0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C1 000 A
Current at 60 °C955 A
Current at 65 °C885 A
Current at 70 °C815 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 690 V74 kA
Power loss, max.123 W
3VA2510-6HN32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2510-6HN32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2510-6HN32-0AF0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2510-6HN32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2510-6HN32-0AF0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

The interrupting capacity at 240 V is 242 kA, at 415 V it is 187 kA, and at 690 V it is 74 kA — figures that govern the available fault current the breaker can safely clear without upstream coordination failure. The ETU350 electronic trip unit provides adjustable long-time (tr) from 0.5 to 17 seconds and short-time delay (tsd) from 0.04 to 0.4 seconds, plus an instantaneous pickup (li) adjustable up to 10 000 A. That means the breaker can be tuned for selectivity with downstream devices, a key requirement for a main or feeder breaker in a distribution panel. Thermal derating is flat at 1 000 A from 40 °C through 55 °C, then drops to 955 A at 60 °C, 885 A at 65 °C, and 815 A at 70 °C.

The breaker measures 210 mm wide, 320 mm high, and 120 mm deep. The width of 210 mm (8.3 in) means it occupies three pole spaces in a typical panelboard or MCC bucket. No communication function is built in; the ETU350 is a standalone electronic trip unit without Modbus or PROFIBUS — coordination settings are adjusted locally via the trip unit dials.

Frequently asked questions

What trip unit does 3VA2510-6HN32-0AF0 use?

It uses the ETU350 electronic trip unit with adjustable long-time, short-time, and instantaneous settings.

MPN
3VA2510-6HN32-0AF0