Skip to main content
Siemens 3VA2510-6HN32-0JL0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2510-6HN32-0JL0 MCCB, 1000 A, 3-Pole

MPN3VA2510-6HN32-0JL0

Siemens SENTRON series, Molded case circuit breaker, 3VA2510-6HN32-0JL0, 3-pole, 1000 A rated continuous current, ETU350 electronic trip unit, 242 kA interrupting at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2510-6HN32-0JL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2510-6HN32-0JL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C1 000 A
Current at 45 °C1 000 A
Current at 50 °C1 000 A
Current at 55 °C1 000 A
Current at 60 °C955 A
Current at 65 °C885 A
Current at 70 °C815 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 690 V74 kA
Power loss, max.123 W
3VA2510-6HN32-0JL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2510-6HN32-0JL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2510-6HN32-0JL0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2510-6HN32-0JL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2510-6HN32-0JL0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

What this 1000 A MCCB does for a line-down call

It's built for line protection — main feeder or large downstream distribution — not motor protection. The interrupting ratings are serious: 242 kA at 240 V, 187 kA at 415 V, 74 kA at 690 V. That SCCR headroom means it can live upstream of a fault without cascading, which is exactly what you want when the main breaker is the only thing between a bolted fault and a whole panel replacement. Thermal derating stays flat at 1000 A all the way to 55 °C. At 60 °C it drops to 955 A, at 70 °C to 815 A. The ETU350 release gives you adjustable Ir from 0.5 to 1.0 × In, plus adjustable short-time (tsd 0.04–0.4 s) and instantaneous (li up to 10 000 A). That's enough flexibility to coordinate with downstream breakers without a separate relay.

Panel fit — 320 × 210 × 120 mm

Footprint: 320 mm tall, 210 mm wide, 120 mm deep. That 210 mm width is a standard 8.3-inch form factor for this amp class. The IP40 front protection means it's splash-safe on the face but not sealed for washdown — this is a panel-mount breaker, not a standalone enclosure.

MPN
3VA2510-6HN32-0JL0