Siemens 3VA2510-6HN42-0AL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2510-6HN42-0AL0 Circuit Breaker, 1000A, 85kA @ 41

MPN3VA2510-6HN42-0AL0

Siemens 3VA2 series, IEC frame 1000 circuit breaker, breaking capacity class H, Icu=85kA @ 415V, 4-pole, line protection ETU350, LSI, In=1000A, overload protection Ir=400A...1000A, short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In, N conductor protection adjustable (OFF, 50%, 100%), nut keeper kit, 2 auxiliary switches HQ, 1 trip alarm switch HQ, 1 electrical alarm switch.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA2510-6HN42-0AL0 is an IEC frame 1000 molded-case circuit breaker from the 3VA2 series, rated at 1000 A continuous and breaking 85 kA at 415 V (class H). The ETU350 trip unit provides LSI protection: long-time (Ir) adjustable 400–1000 A for overload, short-time (Isd) 1.5–10 x Ir for selective coordination downstream, and instantaneous (Ii) fixed at 10 x In for bolted faults. Neutral protection is field-selectable OFF, 50%, or 100% of phase rating.

The 3VA2 platform is Siemens' current-generation IEC breaker line, so firmware and accessory compatibility (auxiliary switches, shunt trips, communication modules) are supported.

Four-pole construction with line and load lugs for 1000 A cable or bus bar. The nut keeper kit (included) retains mounting hardware during vertical or horizontal installation — saves a hand when torquing down in a tight enclosure. Two HQ auxiliary switches and one HQ trip alarm plus one electrical alarm switch are factory-installed. The HQ designation indicates high-rupture-capacity contacts rated for control-circuit isolation without external interposing relays.

Frequently asked questions

What is the breaking capacity of this breaker?

Breaking capacity class H with Icu = 85 kA at 415 V AC. That is the maximum fault current it can safely interrupt at that voltage level.

What trip unit does the 3VA2510-6HN42-0AL0 use?

It uses an ETU350 electronic trip unit with LSI protection: long-time (Ir) adjustable 400–1000 A, short-time (Isd) 1.5–10 x Ir, and instantaneous (Ii) fixed at 10 x In.

Where can I buy the 3VA2510-6HN42-0AL0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.