Siemens 3VA2563-5MN32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2563-5MN32-0DH0 3VA2 IEC Frame 1000, 630A Motor P

MPN3VA2563-5MN32-0DH0

Siemens 3VA2 IEC frame 1000, 3-pole motor protection circuit breaker, 55kA @ 415V, ETU350M LSI trip unit, In=630A, with undervoltage release 208-230V AC, 2 aux switches HQ, 1 trip alarm switch HQ, nut keeper kit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA2563-5MN32-0DH0 is a 3-pole motor protection circuit breaker from the 3VA2 IEC frame 1000 series, rated In=630A with a breaking capacity class M of Icu=55kA at 415V AC. It carries the ETU350M LSI trip unit — that means it gives you long-time (L), short-time (S), and instantaneous (I) protection curves, all adjustable. Overload protection Ir is settable from 250A to 630A; short-circuit protection Isd adjusts from 3 to 15 times Ir, and the fixed instantaneous pickup Ii is 15 x In. This is a motor feeder breaker sized for large induction motors or a group of smaller motors on a common bus.

For motor starting duty, the ETU350M LSI curve lets you coordinate with downstream contactors and overload relays: set Isd high enough to ride through the inrush without nuisance tripping, but low enough to protect the feeder cable. The undervoltage release (UVR) is wired for 208-230V AC, 50/60 Hz — it will drop the breaker if control voltage is lost, which is standard for emergency-stop or safety-shutdown circuits. The nut keeper kit is a panel-builder detail: it retains the mounting nuts inside the enclosure so they don't fall out during installation.

Integration and accessories

The UVR is also pre-installed. The 3VA2 platform accepts plug-in accessories (shunt trip, auxiliary releases, rotary handles) that share the same mounting slots across the frame family.

Frequently asked questions

Where can I buy the 3VA2563-5MN32-0DH0 and what is the lead time?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the delivery window your project needs.

What is the breaking capacity of the 3VA2563-5MN32-0DH0?

The ultimate breaking capacity Icu is 55kA at 415V AC, class M on the IEC frame 1000.

What trip unit does this breaker use?

It uses the ETU350M electronic trip unit with LSI protection — adjustable long-time, short-time, and fixed instantaneous pickup at 15 x In.

MPN