Siemens 3VA2580-5HL32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2580-5HL32-0KL0 SENTRON MCCB, 800 A, 3-Pole, Line

MPN3VA2580-5HL32-0KL0

Siemens SENTRON 3VA2580-5HL32-0KL0, Molded case circuit breaker, Line protection, 3-pole, 800 A rated continuous current, ETU320 electronic trip unit, interrupting capacity 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2580-5HL32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2580-5HL32-0KL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C800 A
Current at 60 °C800 A
Current at 65 °C767 A
Current at 70 °C703 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.135 W
3VA2580-5HL32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2580-5HL32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2580-5HL32-0KL0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2580-5HL32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2580-5HL32-0KL0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

What this 800 A MCCB carries

The Siemens SENTRON 3VA2580-5HL32-0KL0 is a 3-pole molded case circuit breaker rated for line protection, carrying a continuous current rating of 800 A across the ambient range from 40 °C to 60 °C with no derating — at 65 °C it still holds 767 A, and at 70 °C it holds 703 A. The interrupting capacity is 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V — high enough for most main service entrance or large feeder applications where fault currents are substantial. It uses an ETU320 electronic trip unit with adjustable long-time pickup (Ir) from 320 A to 800 A and instantaneous pickup (Ii) from 1,200 A to 8,000 A, plus adjustable long-time delay (tr) from 0.5 to 17 seconds.

Maximum power loss is 135 W, which matters for thermal management inside a sealed enclosure — factor that into your ventilation or derating calculations if the panel runs warm.

Rated insulation voltage is 800 V, operating range from -25 °C to 70 °C, storage from -40 °C to 80 °C, and mechanical endurance is 10,000 operations — figures that match the SENTRON 3VA series specification. If you need those, you'd look at a different 3VA2 option code.

Frequently asked questions

Where can I buy 3VA2580-5HL32-0KL0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution channels — submit a request for quote and availability will be confirmed at that time.

What are the key ratings for 3VA2580-5HL32-0KL0?

It is a 3-pole, 800 A rated continuous current MCCB with interrupting capacity of 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V, using an ETU320 electronic trip unit.

MPN
3VA2580-5HL32-0KL0