Siemens 3VA2580-5HN32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2580-5HN32-0AB0 SENTRON MCCB, 800 A, 3-Pole, ETU3

MPN3VA2580-5HN32-0AB0

Siemens SENTRON 3VA2580-5HN32-0AB0, molded case circuit breaker, 3-pole, 800 A rated continuous current, ETU350 electronic overcurrent release, line protection version, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2580-5HN32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2580-5HN32-0AB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C800 A
Current at 60 °C800 A
Current at 65 °C767 A
Current at 70 °C703 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.135 W
3VA2580-5HN32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2580-5HN32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2580-5HN32-0AB0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2580-5HN32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2580-5HN32-0AB0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

What this 800 A SENTRON MCCB delivers

The Siemens 3VA2580-5HN32-0AB0 is a 3-pole SENTRON molded case circuit breaker rated for 800 A continuous current (Iu) at 40 °C through 60 °C, with a slight derating to 767 A at 65 °C and 703 A at 70 °C. The ETU350 electronic trip unit gives you adjustable long-time delay (tr) from 0.5 to 17 seconds, short-time delay (tsd) from 0.04 to 0.4 seconds, and adjustable Ir up to 800 A with instantaneous pickup (Ii) up to 8000 A. Breaking capacity reaches 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V — enough for high-fault utility feeds or transformer secondaries. This is the line protection version (not feeder or motor protection), so it's optimized for cable and busbar protection in main distribution boards. The ETU350's adjustable time-current curves let you coordinate selectively with downstream breakers — critical for keeping a fault on one branch from dropping the whole plant.

Dimensions are 120 mm deep, 210 mm wide, 320 mm high. The 210 mm width (8.3 in) is the standard 3-pole MCCB footprint for this current class — it fits the same cutout and busbar spacing as other SENTRON 3VA2 frame breakers.

What the ETU350 trip unit lets you set

The electronic overcurrent release (ETU350) is field-adjustable: Ir from 0.4× to 1.0× Iu (320–800 A), long-time delay tr from 0.5 to 17 seconds, short-time pickup Isd from 1.5× to 10× Ir with delay tsd from 0.04 to 0.4 seconds (I²t on/off), and instantaneous Ii from 1.5× to 10× Ir (max 8000 A). Ground fault protection is not included on this variant — the listing confirms 'without' ground fault monitoring.

Frequently asked questions

What is the breaking capacity of 3VA2580-5HN32-0AB0 at different voltages?

187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V. These are the rated ultimate short-circuit breaking capacities (Icu) for this 800 A frame.

Where can I buy 3VA2580-5HN32-0AB0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no automatic stock display applies to this channel.

Does 3VA2580-5HN32-0AB0 include ground fault protection?

No. This variant is specified 'without' ground fault monitoring. If you need ground fault detection, look at the 3VA2 frame variants with the G option in the order code.

What compliance documentation is available for this MCCB?

As a Siemens SENTRON product, it carries CE marking for the European market and is designed to IEC 60947-2. RoHS and REACH declarations are standard from Siemens for current-production 3VA series breakers. UL/CSA listings are not confirmed on this specific order code — verify with the factory if North American approvals are required.