Skip to main content
Siemens 3VA2580-5HN32-0DC0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA2580-5HN32-0DC0 Molded Case Circuit Breaker, 800

MPN3VA2580-5HN32-0DC0

SENTRON 3VA2580-5HN32-0DC0, Molded case circuit breaker, 3-pole, 800 A, interrupting capacity 187 kA at 240 V, 121 kA at 415 V, 53 kA at 690 V, ETU350 electronic trip unit, IP40 front protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2580-5HN32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2580-5HN32-0DC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C800 A
Current at 60 °C800 A
Current at 65 °C767 A
Current at 70 °C703 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.135 W
3VA2580-5HN32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2580-5HN32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2580-5HN32-0DC0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2580-5HN32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2580-5HN32-0DC0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

What this 800 A MCCB delivers

The SENTRON 3VA2580-5HN32-0DC0 is a 3-pole molded case circuit breaker rated for a continuous current of 800 A, with an interrupting capacity of 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V — figures that cover most industrial distribution and motor branch circuits up to those fault levels. The ETU350 electronic trip unit provides adjustable long-time (tr: 0.5–17 s), short-time (tsd: 0.04–0.4 s), and instantaneous (li: up to 8000 A) protection, letting you shape the curve to coordinate with downstream breakers and upstream transformers.

The breaker carries its full 800 A rating from 40 °C through 60 °C ambient; at 65 °C it derates to 767 A, and at 70 °C to 703 A — per the datasheet, no additional correction factor needed for standard panel ambient up to 60 °C. Mounting dimensions are 210 mm wide, 320 mm high, and 120 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or backplate layouts in 800 A switchboards.

MPN
3VA2580-5HN32-0DC0