Siemens 3VA2580-5HN32-0KC0 SENTRON MCCB, 800 A, 187 kA at 24

MPN3VA2580-5HN32-0KC0

Siemens SENTRON 3VA2580-5HN32-0KC0, 3-pole molded case circuit breaker, 800 A rated continuous current, interrupting 187 kA at 240 V, line protection with ETU350 electronic release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2580-5HN32-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2580-5HN32-0KC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C800 A
Current at 60 °C800 A
Current at 65 °C767 A
Current at 70 °C703 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.135 W
3VA2580-5HN32-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2580-5HN32-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2580-5HN32-0KC0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2580-5HN32-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2580-5HN32-0KC0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

Rating and fit for the panel

The Siemens SENTRON 3VA2580-5HN32-0KC0 is a 3-pole molded case circuit breaker (MCCB) rated for 800 A continuous current across the 40 °C to 60 °C ambient range — no derating needed until 65 °C, where it steps to 767 A, and 703 A at 70 °C. That flat thermal curve simplifies panel sizing: the breaker delivers its nameplate 800 A in most standard enclosure conditions without recalculating. Interrupting ratings hit 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V — figures that cover high-fault infrastructure like transformer secondaries or large motor control centers. The ETU350 electronic release allows adjustable long-time pickup (Ir) up to 800 A and instantaneous pickup (Ii) up to 8 000 A, plus short-time delay (tsd) from 0.04 s to 0.4 s. Mounts in a standard panel footprint: 210 mm wide, 320 mm tall, 120 mm deep. No communication module or ground-fault monitoring is built in — this is a straight line-protection device.

Frequently asked questions

What are the key interrupting ratings for 3VA2580-5HN32-0KC0?

At 240 V it interrupts 187 kA, at 415 V it interrupts 121 kA, and at 690 V it interrupts 53 kA — covering high-fault applications like transformer secondaries.

What is the rated continuous current and thermal derating?

Rated continuous current (Iu) is 800 A. It holds 800 A from 40 °C through 60 °C, then derates to 767 A at 65 °C and 703 A at 70 °C.

What is the physical size of 3VA2580-5HN32-0KC0?

Width is 210 mm, height is 320 mm, depth is 120 mm — a standard MCCB panel footprint.

Where can I buy 3VA2580-5HN32-0KC0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.