Skip to main content
Siemens 3VA2580-5KQ32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2580-5KQ32-0AD0 SENTRON MCCB, 800 A, 187 kA at 24

MPN3VA2580-5KQ32-0AD0

Siemens SENTRON 3VA2580-5KQ32-0AD0, molded case circuit breaker, 3-pole, 800 A, 187 kA at 240 V, ETU860 release, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2580-5KQ32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2580-5KQ32-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C800 A
Current at 60 °C800 A
Current at 65 °C767 A
Current at 70 °C703 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.135 W
3VA2580-5KQ32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
3VA2580-5KQ32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2580-5KQ32-0AD0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
3VA2580-5KQ32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2580-5KQ32-0AD0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

MCCB for high-fault main feeders

The Siemens SENTRON 3VA2580-5KQ32-0AD0 is a 3-pole molded case circuit breaker rated for 800 A continuous current at 40 °C, with a 187 kA interrupting capacity at 240 V — enough to sit at the main disconnect on a large industrial switchboard where fault currents are high. The ETU860 electronic trip unit gives you adjustable long-time (tr 0.5–25 s), short-time (tsd 0.05–0.5 s), and instantaneous pickup, plus ground-fault summation sensing on the line conductors. That level of coordination flexibility is what you need for selective tripping downstream of a transformer or generator.

That thermal headroom means you don't have to oversize the frame for a 50 °C switchroom.

Panel fit and communication

Communication function is built in, meaning the ETU860 can talk to a higher-level system for power monitoring and remote trip indication — no separate add-on module needed for basic data.

MPN
3VA2580-5KQ32-0AD0