Siemens 3VA2580-5KQ32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2580-5KQ32-0AF0 MCCB, 800 A, 187 kA at 24

MPN3VA2580-5KQ32-0AF0

Siemens SENTRON 3VA2580-5KQ32-0AF0, molded case circuit breaker, 3-pole, 800 A, 187 kA at 240 V, 121 kA at 415 V, 53 kA at 690 V, ETU860 release, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2580-5KQ32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2580-5KQ32-0AF0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C800 A
Current at 60 °C800 A
Current at 65 °C767 A
Current at 70 °C703 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.135 W
3VA2580-5KQ32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
3VA2580-5KQ32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2580-5KQ32-0AF0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
3VA2580-5KQ32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2580-5KQ32-0AF0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

What this 800 A MCCB delivers

Breaking capacity is the headline: 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V. That kind of interrupting rating means this breaker can sit upstream of a high-fault panel without cascading — it handles the full short-circuit current a large transformer or utility feed can throw at it. Three poles, line-protection version, with an ETU860 electronic trip unit. The ETU860 gives you adjustable long-time pickup (Ir) up to 800 A, short-time pickup and delay (tsd 0.05–0.5 s), and ground-fault monitoring via summation current formation on the L-conductor.

Dimensions: 210 mm wide, 320 mm tall, 120 mm deep. Latching endurance rated at 10 000 operations — that's the mechanical life for the switching mechanism. Not a daily-switch duty cycle, but fine for a distribution feeder that sees infrequent manual operation.

Communication and monitoring

Communication function is present, and the ETU860 supports other measurement functions beyond basic protection — meaning it can report load current, ground-fault levels, and event logs over a communication network. That pulls it into the connected-panel world: you can monitor feeder health from a BMS or SCADA without adding a separate power meter per branch. That's the heat the breaker dumps into the enclosure — factor it into your panel cooling calc, especially if several breakers are stacked in a row.

Frequently asked questions

Does this breaker support ground-fault protection?

Yes, the ETU860 release includes ground-fault monitoring via summation current formation on the L-conductor. It can detect and trip on residual ground currents.

MPN