Skip to main content
Siemens 3VA2580-5KQ32-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2580-5KQ32-0KH0 SENTRON MCCB, 800 A, 3-Pole, ETU8

MPN3VA2580-5KQ32-0KH0

Siemens SENTRON 3VA2580-5KQ32-0KH0, molded case circuit breaker, 3-pole, 800 A, ETU860 electronic trip unit, line protection, 187 kA at 240 V, 121 kA at 415 V, 53 kA at 690 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2580-5KQ32-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2580-5KQ32-0KH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C800 A
Current at 60 °C800 A
Current at 65 °C767 A
Current at 70 °C703 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.135 W

Protection & Trip Unit

3VA2580-5KQ32-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860

Construction & Connection

3VA2580-5KQ32-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2580-5KQ32-0KH0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes

Environmental

3VA2580-5KQ32-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2580-5KQ32-0KH0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

What this 800 A MCCB carries — and where the rating holds

The Siemens SENTRON 3VA2580-5KQ32-0KH0 is a 3-pole molded case circuit breaker rated for 800 A continuous current at 40 °C, with the same 800 A holding through 60 °C — only at 65 °C does it begin to derate to 767 A, and at 70 °C to 703 A. That flat thermal curve means this breaker delivers its full 800 A rating across most normal panel ambient conditions without headroom loss. Its interrupting ratings are tiered by system voltage: 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V. For a main breaker on a 415 V distribution board, the 121 kA SCCR gives substantial fault-clearing headroom — enough to coordinate with downstream feeders without cascading. The ETU860 electronic trip unit provides adjustable long-time pickup (Ir) up to 800 A, short-time delay (tsd) from 0.05 s to 0.5 s, and ground-fault summation sensing on the line conductors. Communication function is built in, so the breaker can report status and trip events to a higher-level control system.

Panel fit — dimensions and integration

The breaker measures 210 mm wide, 320 mm high, and 120 mm deep — a 3-pole frame that fits standard SENTRON mounting patterns. Front protection is IP40, suitable for enclosed panel mounting where the door or cover shields the breaker face from tool drops and dust. Maximum power loss is 135 W at rated current; factor that into enclosure thermal calculations if the panel is densely packed or operating near the 70 °C upper ambient limit.

Frequently asked questions

Where can I buy 3VA2580-5KQ32-0KH0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and availability.

What is 3VA2580-5KQ32-0KH0's interrupting capacity at 415 V?

121 kA at 415 V, which provides strong fault-clearing headroom for main breaker duty on a 415 V distribution board.

What trip unit does this MCCB use?

The ETU860 electronic trip unit with adjustable long-time pickup up to 800 A, short-time delay from 0.05 s to 0.5 s, and ground-fault summation sensing.

MPN
3VA2580-5KQ32-0KH0