Skip to main content
Siemens 3VA2580-5KQ32-0LL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2580-5KQ32-0LL0 SENTRON MCCB, 800 A, 3-Pole, ETU8

MPN3VA2580-5KQ32-0LL0

Siemens SENTRON 3VA2580-5KQ32-0LL0, molded case circuit breaker, 800 A, 3-pole, ETU860 electronic trip unit, line protection, 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2580-5KQ32-0LL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2580-5KQ32-0LL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C800 A
Current at 60 °C800 A
Current at 65 °C767 A
Current at 70 °C703 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.135 W
3VA2580-5KQ32-0LL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
3VA2580-5KQ32-0LL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2580-5KQ32-0LL0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
3VA2580-5KQ32-0LL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2580-5KQ32-0LL0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

The Siemens 3VA2580-5KQ32-0LL0 is a SENTRON molded case circuit breaker (MCCB) rated for 800 A continuous current across the full 40 °C to 60 °C ambient range — no derating needed until 65 °C, where it still holds 767 A, and 703 A at 70 °C. That flat thermal curve means you can size it for a 800 A bus without over-speccing for a warm panel. The 187 kA breaking capacity at 240 V, 121 kA at 415 V, and 53 kA at 690 V covers high-fault installations like transformer secondaries or large motor control centers where upstream coordination demands a stiff interrupt rating. The ETU860 electronic trip unit gives you adjustable long-time (Ir up to 800 A, tr 0.5–25 s) and short-time (tsd 0.05–0.5 s) protection, plus ground-fault summation monitoring on the L conductors — useful for detecting leakage on ungrounded or resistance-grounded systems. It's a line-protection variant, so no N-conductor protection built in; you'd add a separate neutral sensor if needed. The 210 mm width and 320 mm height fit a standard MCCB footprint; depth is 120 mm.

Deployment context

This MCCB mounts in a panel on a standard mounting plate or DIN-rail adapter (not included). The communication function enables remote trip indication, current monitoring, and parameter adjustment via a communication module for PROFIBUS, PROFINET, or Modbus. The 10 000 latching endurance cycles is the mechanical life.

Frequently asked questions

What is the depth of 3VA2580-5KQ32-0LL0?

The depth is 120 mm, with a width of 210 mm and height of 320 mm.

MPN
3VA2580-5KQ32-0LL0