Skip to main content
Siemens 3VA2580-6HN32-0BL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2580-6HN32-0BL0 SENTRON MCCB, 800 A, 3-Pole, ETU3

MPN3VA2580-6HN32-0BL0

Siemens SENTRON 3VA2580-6HN32-0BL0, molded case circuit breaker, 3-pole, 800 A rated continuous current at 40 °C, ETU350 electronic trip unit, breaking capacity 242 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA2580-6HN32-0BL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2580-6HN32-0BL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C800 A
Current at 60 °C800 A
Current at 65 °C767 A
Current at 70 °C703 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 690 V74 kA
Power loss, max.135 W
3VA2580-6HN32-0BL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2580-6HN32-0BL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2580-6HN32-0BL0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2580-6HN32-0BL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2580-6HN32-0BL0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

The Siemens 3VA2580-6HN32-0BL0 is a SENTRON molded case circuit breaker (MCCB) rated for 800 A continuous current at 40 °C, holding that rating flat through 60 °C before derating to 767 A at 65 °C and 703 A at 70 °C. That thermal curve means it handles full load in most ventilated enclosures without forced cooling — important when the panel runs warm near other high-current gear. Breaking capacity sits at 242 kA at 240 V, 187 kA at 415 V, and 74 kA at 690 V — figures that cover high-fault utility feeds and large motor branch circuits where SCCR requirements push past typical 65 kA or 100 kA frames. The 3-pole design with ETU350 electronic trip unit gives adjustable long-time (tr 0.5–17 s), short-time (tsd 0.04–0.4 s), and instantaneous (Ii up to 8000 A) protection curves, letting you coordinate downstream breakers without nuisance trips.

Front IP40 protection suits panel-mount installations behind a sealed enclosure door. Dimensions of 320 mm height, 210 mm width, and 120 mm depth fit standard switchgear cubicle layouts; the 120 mm depth leaves clearance for rear-connected busbars or cable ladders.

The ETU350 electronic trip unit is a microprocessor-based design with adjustable LSI protection (long-time, short-time, instantaneous).

Frequently asked questions

What is the depth of this MCCB?

120 mm depth, with a width of 210 mm and height of 320 mm.

MPN
3VA2580-6HN32-0BL0