Siemens 3VA2580-6HN32-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2580-6HN32-0HH0 SENTRON MCCB, 800 A, 3-Pole, ETU3

MPN3VA2580-6HN32-0HH0

Siemens SENTRON 3VA2580-6HN32-0HH0, molded case circuit breaker, 3-pole, 800 A, ETU350 electronic trip unit, line protection, interrupting capacity 242 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA2580-6HN32-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2580-6HN32-0HH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C800 A
Current at 60 °C800 A
Current at 65 °C767 A
Current at 70 °C703 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 690 V74 kA
Power loss, max.135 W
3VA2580-6HN32-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2580-6HN32-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2580-6HN32-0HH0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2580-6HN32-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2580-6HN32-0HH0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

What this 800 A MCCB delivers

It's configured for line protection — meaning it's the primary overcurrent and short-circuit guard for a feeder or large load, not a motor-protection device with integrated overload class. The interrupting capacity hits 242 kA at 240 V, 187 kA at 415 V, and still holds 74 kA at 690 V, so it handles high-fault-current scenarios like transformer secondaries or large bus risers without cascading upstream. The ETU350 trip unit gives you adjustable long-time pickup (Ir) from 0.5 to 1.0 x Iu, meaning you can set the continuous-current threshold anywhere from 400 A to 800 A to match the actual load. Short-time pickup (Isd) and instantaneous pickup (Ii) are also field-adjustable, with Ii reaching up to 8000 A. That flexibility lets you coordinate selectively with downstream breakers — a real advantage in a multi-level distribution panel where you want the fault cleared closest to the load, not the main.

Frequently asked questions

Where can I buy 3VA2580-6HN32-0HH0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request with your quantity and target delivery window; availability and current pricing are confirmed at quote time.

What is the interrupting capacity of 3VA2580-6HN32-0HH0 at 415 V?

It's rated 187 kA at 415 V. At 240 V it's 242 kA, and at 690 V it's 74 kA.

What trip unit does 3VA2580-6HN32-0HH0 use?

It uses the ETU350 electronic trip unit with adjustable long-time, short-time, and instantaneous pickup settings. Ir is adjustable from 400 A to 800 A, and Ii up to 8000 A.