Skip to main content
Siemens 3VA4135-5ED34-1AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA4135-5ED34-1AA0 SENTRON MCCB, 35 A, 85 kA at 240

MPN3VA4135-5ED34-1AA0
Active

Siemens SENTRON 3VA4135-5ED34-1AA0, molded-case circuit breaker, 3-pole, TM210 release, 35 A at 40 °C, 85 kA at 240 V, 35 kA at 480 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA4135-5ED34-1AA0 — Identification
ParameterValue
Product designationMolded-case circuit breaker
Brand / rangeSENTRON
3VA4135-5ED34-1AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C35 A
Current at 45 °C35 A
Current at 50 °C35 A
Current at 55 °C34 A
Current at 60 °C33 A
Current at 65 °C33 A
Current at 70 °C32 A
Switching capacity classM
Breaking capacity at 240 V85 kA
Power loss, max.9.7 W
3VA4135-5ED34-1AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA4135-5ED34-1AA0 — Construction & Connection
ParameterValue
Main circuit connection typeInfeed side: Low tab
Main circuit connector arrangementoutput side: circular conductor connection
Protection class (IP), frontIP40
3VA4135-5ED34-1AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA4135-5ED34-1AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA4135-5ED34-1AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height129.4 mm
Width76.2 mm
Depth75.1 mm
Height (in)5.09 in
Width (in)3 in
Depth (in)2.96 in

Product details

Its TM210 thermal-magnetic release handles overloads and short-circuits without external trip units — a fixed-trip design that keeps the BOM simple and the panel wiring clean. Rated 35 A continuous at 40 °C, it holds that current up to 50 °C and derates only slightly above: 34 A at 55 °C, 33 A at 65 °C, 32 A at 70 °C.

At 600 Y/347 V it still clears 18 kA. That kind of headroom simplifies coordination studies downstream: you can size branch breakers closer to load without worrying about cascading failure on a bolted fault.

Dimensions are 76.2 mm wide, 129.4 mm high, 75.1 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or direct-mount panel layouts.

MPN
3VA4135-5ED34-1AA0