Siemens SENTRON 3VA4150-5ED34-0AA0, molded-case circuit breaker, 3-pole, TM210 thermal-magnetic release, 50 A at 40 °C, 85 kA at 240 V, 35 kA at 480 V, 690 V rated.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA4150-5ED34-0AA0 — Identification
ParameterValue
Product designationMolded-case circuit breaker
Brand / rangeSENTRON
Product versionSystem protection
3VA4150-5ED34-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C50 A
Current at 45 °C49 A
Current at 50 °C47 A
Current at 55 °C46 A
Current at 60 °C44 A
Current at 65 °C43 A
Current at 70 °C41 A
Switching capacity classM
Breaking capacity at 240 V85 kA
Power loss, max.9.7 W
3VA4150-5ED34-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA4150-5ED34-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeInfeed side: Low tab
Protection class (IP), frontIP40
3VA4150-5ED34-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA4150-5ED34-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA4150-5ED34-0AA0 — Mechanical
ParameterValue
Height129.4 mm
Width76.2 mm
Depth75.1 mm
Height (in)5.09 in
Width (in)3 in
Depth (in)2.96 in

Product details

SENTRON 3VA4150-5ED34-0AA0 — 50 A MCCB, 85 kA at 240 V

The Siemens SENTRON 3VA4150-5ED34-0AA0 is a 3-pole molded-case circuit breaker carrying a 50 A frame rated at 40 °C ambient, with an interrupting capacity of 85 kA at 240 V AC and 35 kA at 480 V AC. The TM210 thermal-magnetic release handles overloads and short-circuits in one compact package, no auxiliary power needed.

Rated 50 A at 40 °C, but the current you can carry drops as the panel warms: 49 A at 45 °C, 47 A at 50 °C, 46 A at 55 °C, 44 A at 60 °C, 43 A at 65 °C, and 41 A at 70 °C. The maximum power loss is 9.7 W, which drives the internal temperature rise inside the enclosure.

Width 76.2 mm, height 129.4 mm, depth 75.1 mm — a standard 3-pole MCCB footprint for DIN-rail or panel-mount.

Frequently asked questions

Where can I buy 3VA4150-5ED34-0AA0 and what is the lead time?

Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest lead time and price.

What is the interrupting rating of 3VA4150-5ED34-0AA0 at 240 V and 480 V?

85 kA at 240 V AC and 35 kA at 480 V AC. At 600 Y/347 V it drops to 18 kA.

What compliance documentation does this breaker carry?

It carries UL file MEAB (UL 489 listing) and is rated for 690 V AC operation. The SENTRON series typically meets IEC 60947-2 requirements as well.

MPN