Siemens 3VA4170-4ED34-3AA0 Circuit Breaker, 70 A, 25 kA @ 48

MPN3VA4170-4ED34-3AA0
Active

Siemens 3VA4 UL Frame 125, 3-pole circuit breaker, breaking capacity class S 25 kA @ 480 V, line protection TM210, FTFM, In=70 A overload protection Ir=70 A permanently set, short-circuit protection Ii=10 x In.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Specifications

3VA4170-4ED34-3AA0 — Specifications
ParameterValue
Group codeP360
Product group5385
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
SeriesOrdering Data Overview
Export control regulationsAL : N / ECCN : EAR99
Compliance with the substance restrictions according to RoHS directiveSince: 13-05-19

Product details

The Siemens 3VA4170-4ED34-3AA0 is a 3-pole molded case circuit breaker in the 3VA4 UL Frame 125 series, rated for line protection with a TM210 thermal-magnetic trip unit. Overload protection is fixed at 70 A (Ir = 70 A), and the short-circuit magnetic trip is set at 10× In (700 A). The breaking capacity class S delivers 25 kA at 480 V — enough for most commercial and light industrial distribution panels without cascading upstream breakers.

SCCR and selectivity

The 25 kA interrupting rating at 480 V places this breaker in the S-class of the 3VA4 family. For a 70 A fixed-trip breaker, that means it can clear a fault up to 25,000 A without welding contacts or venting gas into the enclosure. In a panel with a 65 kA available fault current, you'd need a current-limiting upstream breaker or fuse to coordinate — this breaker alone won't hold that. Pair it with a properly rated main, and the selectivity tables in the Siemens coordination manual apply.

Panel integration

Mounts on a standard DIN rail or panel-mount via the 3VA4 mounting accessories. The TM210 trip unit is non-interchangeable — Ir is fixed at 70 A, so if the load changes, the breaker itself must be replaced. Line and load lugs accept copper or aluminum conductors. The FTFM (fixed thermal, fixed magnetic) trip means no field adjustment of the magnetic pickup; it's locked at 10× In.

Frequently asked questions

What is the interrupting rating of this breaker?

The breaking capacity class S provides 25 kA at 480 V.

Can the overload protection setting be adjusted?

No, the TM210 trip unit has a fixed thermal setting Ir = 70 A and a fixed magnetic setting Ii = 10 × In (700 A). No field adjustment is possible.

What compliance documentation is available for the 3VA4170-4ED34-3AA0?

The part is RoHS compliant since 13-05-19 and carries a REACH Article 33 notification for lead (CAS 7439-92-1) above 0.1% w/w. Export control is AL: N / ECCN: EAR99.

Where can I buy the 3VA4170-4ED34-3AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.