Skip to main content
Siemens 3VA4170-6ED34-3AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA4170-6ED34-3AA0 Circuit Breaker, 70 A, 65 kA @ 48

MPN3VA4170-6ED34-3AA0
Active

Siemens 3VA4 UL Frame 125, 3-pole circuit breaker, 70 A TM210 line protection, 65 kA interrupting capacity at 480 V, fixed Ir=70 A, fixed Ii=10 x In, FTFM.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Specifications

3VA4170-6ED34-3AA0 — Specifications
ParameterValue
Group codeP360
Product group5385
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
SeriesOrdering Data Overview
Export control regulationsAL : N / ECCN : EAR99
Compliance with the substance restrictions according to RoHS directiveSince: 13-05-19

Product details

What the ratings mean for the panel

The Siemens 3VA4170-6ED34-3AA0 is a 3-pole molded-case circuit breaker in the 3VA4 UL Frame 125 series, rated for line protection with a TM210 thermal-magnetic trip unit. The 65 kA interrupting capacity at 480 V means it can safely clear a fault up to that level on a 480 VAC distribution bus without upstream devices needing to coordinate — a strong SCCR for most industrial panelboards. The overload protection is set permanently at Ir=70 A, and the short-circuit pickup is fixed at Ii=10 x In (700 A). That fixed trip setting simplifies BOM consistency: every unit delivers the same protection curve, no field-adjustment errors. The FTFM (Fixed Thermal, Fixed Magnetic) trip unit eliminates the need for calibration or seal-wire management on the line. For a panel builder, this means one less variable during FAT — the breaker behaves identically unit-to-unit. The 3-pole construction fits standard 3-phase feeder or branch circuits in switchboards and panelboards rated up to 480 V.

Sourcing and lifecycle reality

Export control is straightforward: AL N / ECCN EAR99, so no special licensing is required for most destinations. RoHS compliance is confirmed since 13-05-19, and REACH Article 33 disclosure notes lead (CAS 7439-92-1) above 0.1% w/w in the current candidate list — a standard declaration for electrical components with lead-bearing alloys.

Integration notes for the panel

The 3VA4 UL Frame 125 breaker mounts directly to a panelboard bus or can be installed in a standalone enclosure. The 3-pole form factor with line and load lugs accepts copper or aluminum conductors sized for the 70 A continuous rating. The thermal-magnetic trip unit is non-interchangeable — the TM210 is integral to the frame, so the protection settings are fixed at the factory. No accessory slot for shunt trips or auxiliary contacts is described in the base listing; verify the specific order code suffix if add-on modules are required for remote trip indication or undervoltage release.

Frequently asked questions

How do I get current pricing and availability for 3VA4170-6ED34-3AA0?

Pricing and availability are confirmed at quote time. Submit an RFQ through the storefront; the made-to-order status means the factory schedule and current material costs determine the lead time and price — no shelf stock exists.

What is the interrupting rating of this breaker?

The 3VA4170-6ED34-3AA0 is rated 65 kA at 480 V, breaking capacity class H. That is sufficient for most industrial main and feeder applications with high available fault current.

What compliance documentation does this brand provide for 3VA4170-6ED34-3AA0 (RoHS, REACH, UL, IEC)?

RoHS compliance is confirmed since 13-05-19. REACH Article 33 disclosure identifies lead (CAS 7439-92-1) above 0.1% w/w. The breaker is UL-listed under the 3VA4 UL Frame 125 series. Export control is AL N / ECCN EAR99.

MPN